Sample Record for 2026-02-10-1
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 1000510 DEA: 060W79U4 EFIS: 0622000189
QA Service Level: 1
DIST-CO-RTE-PM: 06-KER,TUL-99-56.4/57.6,0.0/13.5
Work Description: RDWY EXC, HMA, AGGREGATE BASE, CRCP, SIGN STR, AND STR EXC.
Location Description: KERN AND TULARE COUNTIES IN AND NEAR DELANO FROM 0.2 MILE SOUTH OF CECIL AVENUE OVERCROSSING TO 0.7 MILE NORTH OF AVENUE 100 OVERCROSSING
Contractor Name: Security Paving Company, Inc.
Contractor Address: 2915 Fairhaven Drive, Bakersfield, CA 93308
Resident Engineer: Jake Garcia Structure Rep.: Raman Guraya
Sample Information
DIME Sample ID: 2026-02-10-1
TL Number from the TL Form: L191-018-26
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 02/10/2026
Date that the sample was received by the laboratory/organization performing the testing: 02/12/2026
The quantity of what the sample constitutes: 8
A brief description of the sample: #6 x 2'-0"
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: TNT Rebar
Material Information
Production or Authorization Testing: Authorization Testing
Service or Ultimate: Ultimate
Rebar Heat Number(s): 1201071818
Hoop Manufacturer Lot Number(s): 1
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Size: #6
Diameter of Hoop: 2'-0"
Epoxy Coated: No
Epoxy Coating Color: NA
Rebar Manufacturer: Nucor
Welding Company: TNT Rebar Company
Coating Standards: Uncoated
Weld Type: Flash Welded
Test Results
Test 1 of 1
DIME Test ID: 2026-02-10-1-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 02/17/2026
Date Tested: 02/17/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Samples
|
4
|
| Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By | | 1 | 1 | 6 | 0.44 | 39830 | 90500 | ok necking | Kleinfelder | | 2 | 1 | 6 | 0.44 | 39450 | 89500 | ok necking | Kleinfelder | | 3 | 1 | 6 | 0.44 | 39740 | 90500 | ok necking | Kleinfelder | | 4 | 1 | 6 | 0.44 | 39970 | 91000 | ok necking | Kleinfelder |
| |
|
UTM
|
NA
|
|
Temperature
|
0 f
|