Sample Record for 2026-01-15-50

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001375 DEA: 040A53T4 EFIS: 0421000155 COOP: 040A53TCM QA Service Level: 1
DIST-CO-RTE-PM: 04-SOL-80-L1.8/L3.2
Work Description: Construct I-80 WB Truck Scales
Location Description: CONSTRUCTION ON STATE HIGHWAY IN SOLANO COUNTY IN AND NEAR FAIRFIELD ON ROUTE 12 FROM THE 80/12 EAST JUNCTION TO 0.9 MILE EAST OF CHADBOURNE ROAD UNDERCROSSING AND ON ROUTE 80 FROM 0.5 MILE WEST OF DAN WILSON CREEK BRIDGE TO WEST TEXAS STREET UNDERCROSSI
Contractor Name: Kiewit Infrastructure West Co.
Contractor Address: 4650 Business Center Drive, Fairfield, CA 94534
Resident Engineer: Darren Isada Structure Rep.: Nana Budu

Sample Information

DIME Sample ID: 2026-01-15-50
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Vallejo Field Laboratory
Sample Organization Contact: 9166394315
Type of Sample: Quality Assurance
Type of Material: Precast Concrete
Sample Taken Date: 01/15/2026
Date that the sample was received by the laboratory/organization performing the testing: 01/20/2026
The quantity of what the sample constitutes: 41 cubic yards
A brief description of the sample: 3 - 4x8" Concrete Cylinders
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name: Suisun Creek Bridge
The fabricator/manufacturer/facility name: KIE-CON, INC

Material Information

The concrete mix design number: K7595-14312
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 126936
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Sample in wheelbarrow from 2nd load of concrete
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2026-01-15-50-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 02/13/2026
Date Tested: 02/12/2026
Submitted By Organization: Quality Assurance Engineering, Inc dba Consolidated Engineering Laboratories
Organization Address: 690 Walnut,
Organization City: vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: yannick.aranas@dot.ca.gov
Organization Phone: (916) 639-4315
General Comments for this Test: Predicted 10 Kips compression
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Apparent mass of submerged cylinder 1 9 lb
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 11720 psi
Maximum load on cylinder 1 147740 lb
Maximum load on cylinder 2 146210 lb
Maximum load on cylinder 3 148040 lb
Compressive strength of cylinder 1 11750.0 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 11630.0 psi
Compressive strength of cylinder 3 11780 psi
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data