Print Report | Back to Sample Detail

Sample Record for 2026-02-06-9

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000541 DEA: 09374704 EFIS: 0918000019 QA Service Level: 1
DIST-CO-RTE-PM: 09-INY-168,395-17.6/18.3,114.9/117.8
Work Description: HMA (TYPE A), MINOR CONCRETE, AND LIGHTING.
Location Description: INYO COUNTY IN AND NEAR BISHOP ON ROUTE 395 FROM 0.1 MILE SOUTH OF JAY STREET TO BARLOW LANE AND ON ROUTE 168 FROM PIONEER LANE TO ROUTE 395
Contractor Name: PAPICH CONSTRUCTION COMPANY, INC.
Contractor Address: P.O. BOX 2210, PISMO BEACH, CA 93448-2210
Resident Engineer: John Gentry Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-02-06-9
TL Number from the TL Form:
Sample Submitted By Organization: CT D09 - Bishop Field Laboratory
Sample Organization Contact: (760) 872-5211
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 02/06/2026
Date that the sample was received by the laboratory/organization performing the testing: 02/08/2026
The quantity of what the sample constitutes: 6x(4x8 cylinders)
A brief description of the sample: High Light electric decorative lighting piles 5 thru 9
From where was the sample collected: Source
Laboratory sample identification: 5271
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: 7-11 Materials

Material Information

The concrete mix design number: 851456A6
The truck number from where the sample was collected: 83989
The batch plant ticket number from where the sample was collected: 956923
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Bishop pavement near Tatum’s ranch. Pile 5 thru 9
Where the material sample would have been placed if not sampled: In pile
From Lot No.:
Bag Lot No.:

Test Results

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2026-02-06-9-1CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders02/08/2026Not scheduledDarrell BiedermanCT D09 - Bishop Field LaboratoryDerek Carrington