Sample Record for 2026-02-06-7
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 994326 DEA: 051C3604 EFIS: 0512000134
QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-217-0.9/1.4
Work Description: REPLACE BRIDGE.
Location Description: SANTA BARBARA COUNTY NEAR GOLETA FROM 0.2 MILE EAST OF GOLETA SLOUGH BRIDGE TO 0.4 MILE EAST OF SAN JOSE CREEK BRIDGE
Contractor Name: MCM CONSTRUCTION
Contractor Address: 6413 32nd Street, North Highlands, Ca 95660
Resident Engineer: Manny Yogarajah Structure Rep.: Fabian Velasco
Sample Information
DIME Sample ID: 2026-02-06-7
TL Number from the TL Form: 0101
Sample Submitted By Organization: CT SC - 3675 - Santa Barbara 1
Sample Organization Contact: (805) 441-6932
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 02/06/2026
Date that the sample was received by the laboratory/organization performing the testing: 02/10/2026
The quantity of what the sample constitutes: 4 QA samples
A brief description of the sample: ZapScrew Lock couplers for BOX CULVERT PUC #9 verticals being outside of the concrete pour
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier: 51-0369
Structure name: GOLETA PUC
The fabricator/manufacturer/facility name: BarSplice Products, Inc
Material Information
Production or Authorization Testing: Production Testing
Service or Ultimate: Service
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: Cascade Steel
Coupler Manufacturer: BARSPLICE
Intermediate Assembler or Fabricator:
Rebar Size: #9
Coupler Model: 09SZBA_A92
Coating Standards: Uncoated
Shape of Rebar: Straight
Rebar Hoop Diameter:
Rebar Hoop Fabricator:
Coupler Component Heat/Lot Number(s): 4000027982
Rebar Heat Number(s): 485725
Rebar Size 2 :
Coupler Unique ID: SL-17-03
Test Results
Test 1 of 1
DIME Test ID: 2026-02-06-7-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Verified Date: 02/13/2026
Date Tested: 02/13/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of Samples
|
4
|
| Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By | | 1 | 4000027982 | 9 | 1 | 0.009 | 89120 | 89000 | service splice | Kleinfelder | | 2 | 4000027982 | 9 | 1 | 0 | 89140 | 89000 | service splice | Kleinfelder | | 3 | 4000027982 | 9 | 1 | 0 | 91630 | 91500 | service splice | Kleinfelder | | 4 | 4000027982 | 9 | 1 | 0 | 88930 | 89000 | service splice | Kleinfelder |
| |
|
Temperature
|
0 f
|
|
UTM
|
NA
|
|
Halo ID
|
NA
|