Sample Record for 2026-01-30-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993798 DEA: 09366804 EFIS: 0916000021 QA Service Level: 1
DIST-CO-RTE-PM: 09-INY-395-117.3/117.9
Work Description: MEADOW FARMS ADA
Location Description: INYO COUNTY NEAR BISHOP FROM 0.1 MILE EAST OF SEE VEE LANE TO BARLOW LANE
Contractor Name: PAPICH CONSTRUCTION COMPANY, INC.
Contractor Address: P.O. BOX 2210, PISMO BEACH, CA 93448-2210
Resident Engineer: Adam Zumstein Structure Rep.: Mulugheta Belay

Sample Information

DIME Sample ID: 2026-01-30-2
TL Number from the TL Form:
Sample Submitted By Organization: CT D09 - Bishop Field Laboratory
Sample Organization Contact: (760) 872-5211
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 01/30/2026
Date that the sample was received by the laboratory/organization performing the testing: 01/31/2026
The quantity of what the sample constitutes: 3 4”x8” cylinders and 2 6x12”
A brief description of the sample: Concrete for pedestrian bridge
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name: Pedestrian Bridge
The fabricator/manufacturer/facility name: 7-11 Materials Bishop

Material Information

The concrete mix design number: 851259C6
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 1
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Meadow Farms pedestrian bridge
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2026-01-30-2-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 02/27/2026
Date Tested: 02/27/2026
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: Pedestrian Bridge PCC-001
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 3.99 in
Average diameter of cylinder 2 3.99 in
Average diameter of cylinder 3 3.99 in
Cross sectional area of cylinder 1 12.5 in^2
Cross sectional area of cylinder 2 12.5 in^2
Cross sectional area of cylinder 3 12.5 in^2
Compressive strength (to nearest 10 psi) 6170 psi
Maximum load on cylinder 1 78230 lb
Maximum load on cylinder 2 75340 lb
Maximum load on cylinder 3 77710 lb
Compressive strength of cylinder 1 6258.4 psi
Type of fracture pattern of cylinder 1 1
Compressive strength of cylinder 2 6027.2 psi
Compressive strength of cylinder 3 6216.8 psi
Type of fracture pattern of cylinder 2 1
Type of fracture pattern of cylinder 3 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data0 hours