Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1001375 DEA: 040A53T4 EFIS: 0421000155 COOP: 040A53TCM
QA Service Level: 1
DIST-CO-RTE-PM: 04-SOL-80-L1.8/L3.2
Work Description: Construct I-80 WB Truck Scales
Location Description: CONSTRUCTION ON STATE HIGHWAY IN SOLANO COUNTY IN AND NEAR FAIRFIELD ON ROUTE 12 FROM THE 80/12 EAST JUNCTION TO 0.9 MILE EAST OF CHADBOURNE ROAD UNDERCROSSING AND ON ROUTE 80 FROM 0.5 MILE WEST OF DAN WILSON CREEK BRIDGE TO WEST TEXAS STREET UNDERCROSSI
Contractor Name: Kiewit Infrastructure West Co.
Contractor Address: 4650 Business Center Drive, Fairfield, CA 94534
Resident Engineer: Darren Isada Structure Rep.: Nana Budu
DIME Sample ID: 2026-01-22-3
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 01/22/2026
Date that the sample was received by the laboratory/organization performing the testing: 01/27/2026
The quantity of what the sample constitutes: 28
A brief description of the sample: ASTM F1554 Gr. 55 3/4" Heavy Hex Bolt
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Portland Bolt
Rocap Number(s):
Heat Number(s): 3140713
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: ASTM F1554 Grade 55
Bolt Length(s): 20"
Nut Specification: N/A
Washer Specification: N/A
Finish: HDG
Diameter/Size: 3/4"
Bolt Mfg. Lot Number:
Rocap Test Requirement(s):
Lubricant Requirements(s):
Washer Inner Diameter(s):
DIME Test ID: 2026-01-22-3-1
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 02/02/2026
Date Tested: 01/28/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
3140713
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
YELLOW
|
|
Size
|
0.75 in
|
|
Bolt Length
|
20 in
|
|
Pitch Diameter
|
0.6965 in
|
|
Pitch Diameter 2nd
|
0.6965 in
|
DIME Test ID: 2026-01-22-3-2
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 02/02/2026
Date Tested: 01/30/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
3140713
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
no data in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
5 mils
|
DIME Test ID: 2026-01-22-3-3
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 02/02/2026
Date Tested: 01/30/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Bolt Samples
|
1
|
| Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | | 1A | 3140713 | 0.75 | 28020 | 0 | 0 | NA | WSP |
| |
|
UTM
|
NA
|
|
Temperature
|
0 f
|