Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1001219 DEA: 021J8904 EFIS: 0221000006
QA Service Level: 1
DIST-CO-RTE-PM: 02-SHA-5-R30.5/R31.0
Work Description: REPLACE PAVEMENT AND PLACE POLYESTER CONCRETE OVERLAY.
Location Description: SHASTA COUNTY NEAR O\'BRIEN FROM 0.1 MILE SOUTH OF TUNNEL GULCH VIADUCT TO THE O\'BRIEN REST AREA
Contractor Name: MCCUEN CONSTRUCTION, INC.
Contractor Address: 3269 SWETZER ROAD, Loomis CA 95650
Resident Engineer: Kyle Higgins Structure Rep.: Chris Brace
DIME Sample ID: 2025-09-05-101
TL Number from the TL Form:
Sample Submitted By Organization: G3 Quality, Incorporated - Cerritos
Sample Organization Contact: (562) 321-9840
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 09/05/2025
Date that the sample was received by the laboratory/organization performing the testing: 09/05/2025
The quantity of what the sample constitutes: 20
A brief description of the sample: 4 x 8 Concrete Cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 80373-1 TP Set 1
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Precision Concrete Materials
The concrete mix design number: 80373-1 TP
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 0
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Precision Concrete Yard
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2025-09-05-101-1
Test Method: CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement Concrete
Verified Date: 04/09/2026
Date Tested: 09/05/2025
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2025-09-05-101-2
Test Method: CTM 518-June 2010: Method of Test for Unit Weight of Fresh Concrete
Verified Date: 04/09/2026
Date Tested: 09/05/2025
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit weight of the concrete
|
140.8 lb/ft^3
|
|
Cement content
|
no data0 lb/yd^3
|
DIME Test ID: 2025-09-05-101-3
Test Method: CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 04/09/2026
Date Tested: 09/05/2025
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2025-09-05-101-4
Test Method: CTM 556-January 2018: Method of Test for Slump of Fresh Portland Cement Concrete
Verified Date: 04/09/2026
Date Tested: 09/05/2025
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2025-09-05-101-5
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 04/09/2026
Date Tested: 09/05/2025
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
5
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Average diameter of cylinder 1
|
4.01 in
|
|
Average diameter of cylinder 2
|
4.01 in
|
|
Average diameter of cylinder 3
|
4.01 in
|
|
Average diameter of cylinder 4
|
4.01 in
|
|
Average diameter of cylinder 5
|
4.01 in
|
|
Cross sectional area of cylinder 1
|
12.63 in^2
|
|
Cross sectional area of cylinder 2
|
12.63 in^2
|
|
Cross sectional area of cylinder 3
|
12.63 in^2
|
|
Cross sectional area of cylinder 4
|
12.63 in^2
|
|
Cross sectional area of cylinder 5
|
12.63 in^2
|
|
Compressive strength (to nearest 10 psi)
|
2530 psi
|
|
Maximum load on cylinder 1
|
34750 lb
|
|
Maximum load on cylinder 2
|
31160 lb
|
|
Maximum load on cylinder 3
|
31810 lb
|
|
Maximum load on cylinder 4
|
29960 lb
|
|
Maximum load on cylinder 5
|
32090 lb
|
|
Type of fracture pattern of cylinder 1
|
5
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Type of fracture pattern of cylinder 3
|
2
|
|
Type of fracture pattern of cylinder 4
|
5
|
|
Type of fracture pattern of cylinder 5
|
3
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Correction factor for cylinder 4
|
1
|
|
Correction factor for cylinder 5
|
1
|
|
Age of specimen
|
no data0 days
|
|
Age of specimen in hours
|
2 hours
|
DIME Test ID: 2025-09-05-101-6
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 04/09/2026
Date Tested: 09/08/2025
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
5
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Average diameter of cylinder 1
|
44.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Average diameter of cylinder 4
|
4.00 in
|
|
Average diameter of cylinder 5
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Cross sectional area of cylinder 4
|
12.57 in^2
|
|
Cross sectional area of cylinder 5
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
5820 psi
|
|
Maximum load on cylinder 1
|
62540 lb
|
|
Maximum load on cylinder 2
|
64850 lb
|
|
Maximum load on cylinder 3
|
60980 lb
|
|
Maximum load on cylinder 4
|
62730 lb
|
|
Maximum load on cylinder 5
|
64950 lb
|
|
Type of fracture pattern of cylinder 1
|
3
|
|
Type of fracture pattern of cylinder 2
|
3
|
|
Type of fracture pattern of cylinder 3
|
3
|
|
Type of fracture pattern of cylinder 4
|
3
|
|
Type of fracture pattern of cylinder 5
|
3
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Correction factor for cylinder 4
|
1
|
|
Correction factor for cylinder 5
|
1
|
|
Age of specimen
|
3 days
|
|
Age of specimen in hours
|
no data0 hours
|
DIME Test ID: 2025-09-05-101-7
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 04/09/2026
Date Tested: 10/03/2025
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
5
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Average diameter of cylinder 4
|
4.00 in
|
|
Average diameter of cylinder 5
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Cross sectional area of cylinder 4
|
12.57 in^2
|
|
Cross sectional area of cylinder 5
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
5820 psi
|
|
Maximum load on cylinder 1
|
72360 lb
|
|
Maximum load on cylinder 2
|
76120 lb
|
|
Maximum load on cylinder 3
|
73580 lb
|
|
Maximum load on cylinder 4
|
70410 lb
|
|
Maximum load on cylinder 5
|
73360 lb
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Type of fracture pattern of cylinder 3
|
2
|
|
Type of fracture pattern of cylinder 4
|
2
|
|
Type of fracture pattern of cylinder 5
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Correction factor for cylinder 4
|
1
|
|
Correction factor for cylinder 5
|
1
|
|
Age of specimen
|
28 days
|
|
Age of specimen in hours
|
no data0 hours
|