Print Report | Back to Sample Detail

Sample Record for 2026-01-15-5

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000402 DEA: 11430384 EFIS: 1118000114 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-805-23.7/28.5
Work Description: REPLACE DRAINAGE, CONCRETE PAVEMENT, AND MODIFY ELECTRICAL SYSTEMS.
Location Description: SAN DIEGO COUNTY IN SAN DIEGO FROM 0.1 MILE NORTH OF ROUTE 805/52 SEPARATION TO ROUTE 5/805 SEPARATION
Contractor Name: HAZARD CONSTRUCTION ENGR, LLC
Contractor Address: 10529 VINE STREET, LAKESIDE, CA 92040
Resident Engineer: Karl Hartline Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-01-15-5
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 01/15/2026
Date that the sample was received by the laboratory/organization performing the testing: 01/15/2026
The quantity of what the sample constitutes: 2 boxes
A brief description of the sample: Normal Production
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Otay

Material Information

HMA Type: Type A HMA
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number: 320200 Otay Val
Binder content (%): 4.9
Virgin binder PG: PG58-16
Design binder PG: PG 64-16
Binder Supplier: Valero
RAP content (%): 22
WMA Additives: No
Antistrip type: None

Test Results

Test 1 of 2

DIME Test ID: 2026-01-15-5-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 01/27/2026
Date Tested: 01/22/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: 5.50%>4.9+-0.5 does not comply.
Test Result Compliance: does not comply
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 4035.1 g
Mass of the specimen and specimen basket assembly prior to ignition 5596.2 g
Mass of HMA Sample prior to ignition 1561.1 g
Corrected Asphalt Binder Content 5.5 %
Mass Loss 93.4 g
Mass of aggregate remaining after ignition 1467.7 g
Correction Factor (Percent by mass of HMA Specimen) 0.48 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C

Test 2 of 2

DIME Test ID: 2026-01-15-5-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 01/27/2026
Date Tested: 01/22/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? SI Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7475.6 grams
Mass of oven-dry sample in air for Sample 1 1528.2 grams
Mass of container filled with the sample and water for Sample 1 8391.6 grams
Temperature of Water 78 °F
Specific Gravity for Sample 1 2.496
Theoretical maximum density at 25°C (77°F) 2488.8 kg/m^3