Project Information

Project ID: 994901 DEA: 112T3434 EFIS: 1120000081 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-805-5.1/8.3
Work Description: SOUNDWALLS, WIDEN FREEWAY, STRUCTURES, LANDSCAPE AND ELECTRICAL.
Location Description: SAN DIEGO COUNTY IN CHULA VISTA FROM PALOMAR STREET OVERCROSSING TO 0.5 MILE NORTH OF BONITA ROAD UNDERCROSSING
Contractor Name: WALSH CONSTRUCTION COMPANY II, LLC
Contractor Address: 1260 Corona Pointe Court #201
Resident Engineer: Tan Cao Structure Rep.: Daniela Lopez

Sample Information

DIME Sample ID: 2026-01-15-2
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 01/15/2026
Date that the sample was received by the laboratory/organization performing the testing: 01/15/2026
The quantity of what the sample constitutes: Field Sample
A brief description of the sample: Field Sample
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Associated Otay

Material Information

The concrete mix design number: 55723740
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 1
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Field Sample
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 9

DIME Test ID: 2026-01-15-2-4
Test Method: CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement Concrete
Verified Date: 01/16/2026
Date Tested: 01/15/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: not applicable
Additional Comments When Verified:
Temperature 78 F

Test 2 of 9

DIME Test ID: 2026-01-15-2-1
Test Method: CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 01/16/2026
Date Tested: 01/15/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Target 1.5 %
Test Result Compliance: complies
Additional Comments When Verified:
Air Content 1.6 %

Test 3 of 9

DIME Test ID: 2026-01-15-2-2
Test Method: CTM 518-June 2010: Method of Test for Unit Weight of Fresh Concrete
Verified Date: 01/21/2026
Date Tested: 01/15/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Not Applicable
Test Result Compliance: not applicable
Additional Comments When Verified:
Unit weight of the concrete 72.94 lb/ft^3
Volume of the concrete 19.996 yd^3
Cement content 201.04 lb/yd^3

Test 4 of 9

DIME Test ID: 2026-01-15-2-3
Test Method: CTM 556-January 2018: Method of Test for Slump of Fresh Portland Cement Concrete
Verified Date: 01/16/2026
Date Tested: 01/15/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 4.0 +/- 1.5 % Tested 3.5%
Test Result Compliance: complies
Additional Comments When Verified:
Slump 3.5 inch

Test 5 of 9

DIME Test ID: 2026-01-15-2-9
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 01/21/2026
Date Tested: 01/20/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: 5 Day Does Not Comply Target 4500 psi Tested an Avg of 2740 psi
Test Result Compliance: does not comply
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 5.99 in
Average diameter of cylinder 2 5.99 in
Cross sectional area of cylinder 1 28.18 in^2
Cross sectional area of cylinder 2 28.18 in^2
Compressive strength (to nearest 10 psi) 2740 psi
Maximum load on cylinder 1 72280 lb
Maximum load on cylinder 2 82121 lb
Compressive strength of cylinder 1 2564.9 psi
Type of fracture pattern of cylinder 1 1
Compressive strength of cylinder 2 2914.2 psi
Type of fracture pattern of cylinder 2 1
Comment on any defect in either specimen or caps (Max 250 Characters) N / A
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 5 days
Age of specimen in hours no data0 hours

Test 6 of 9

DIME Test ID: 2026-01-15-2-5
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 02/05/2026
Date Tested: 01/22/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: 7 Day Does Not Comply Target 4500 psi Tested an Avg of 2977 psi
Test Result Compliance: does not comply
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 5.99 in
Average diameter of cylinder 2 5.99 in
Cross sectional area of cylinder 1 28.18 in^2
Cross sectional area of cylinder 2 28.18 in^2
Compressive strength (to nearest 10 psi) 2980 psi
Maximum load on cylinder 1 83580 lb
Maximum load on cylinder 2 84185 lb
Compressive strength of cylinder 1 2965.9 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 2987.4 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 7 days
Age of specimen in hours no data0 hours

Test 7 of 9

DIME Test ID: 2026-01-15-2-6
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 02/05/2026
Date Tested: 01/29/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: 14 Day, 3680psi<4500PSI Does not comply.
Test Result Compliance: does not comply
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 5.99 in
Average diameter of cylinder 2 5.99 in
Cross sectional area of cylinder 1 28.18 in^2
Cross sectional area of cylinder 2 28.18 in^2
Compressive strength (to nearest 10 psi) 3680 psi
Maximum load on cylinder 1 107790 lb
Maximum load on cylinder 2 99725 lb
Compressive strength of cylinder 1 3825.1 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 3538.9 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 14 days
Age of specimen in hours no data0 hours

Test 8 of 9

DIME Test ID: 2026-01-15-2-7
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 02/12/2026
Date Tested: 02/12/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: 28 Day Complies.
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 5.99 in
Average diameter of cylinder 2 5.99 in
Cross sectional area of cylinder 1 28.18 in^2
Cross sectional area of cylinder 2 28.18 in^2
Compressive strength (to nearest 10 psi) 4760 psi
Maximum load on cylinder 1 128795 lb
Maximum load on cylinder 2 139620 lb
Compressive strength of cylinder 1 4570.4 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 4954.6 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 28 days
Age of specimen in hours no data0 hours

Test 9 of 9

DIME Test ID: 2026-01-15-2-8
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 02/27/2026
Date Tested: 02/26/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: 42 Day, Complies
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 5.99 in
Average diameter of cylinder 2 5.99 in
Cross sectional area of cylinder 1 28.18 in^2
Cross sectional area of cylinder 2 28.18 in^2
Compressive strength (to nearest 10 psi) 5070 psi
Maximum load on cylinder 1 146815 lb
Maximum load on cylinder 2 138775 lb
Compressive strength of cylinder 1 5209.9 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 4924.6 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 42 days
Age of specimen in hours no data0 hours