Sample Record for 2026-01-09-4
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 215365 DEA: 120Q9704 EFIS: 1218000010
QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-405-0/11.4
Work Description: I-405 improvement project from I-5 to Harbor Boulevard including extend pavement life, improve safety, enhance traffic operation, and incorporate Intelligent Transportation Systems (ITS).
Location Description: Orange County I-405 PM 0 - 11.4
Contractor Name: Guy F. Atkinson
Contractor Address: 38 Executive Park, IRVINE CA 92614
Resident Engineer: Mona Shahidi Structure Rep.: Brian Vo
Sample Information
DIME Sample ID: 2026-01-09-4
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 01/09/2026
Date that the sample was received by the laboratory/organization performing the testing: 01/20/2026
The quantity of what the sample constitutes: 40 pcs
A brief description of the sample: 3/4(10)X 2-1/2 A325-1 BOLT HDG
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: St.Louis Screw and Bolt
Material Information
Rocap Number(s): TT0197000
Heat Number(s): Bolt-1000130966, Nut-20958990, Wash-244757
Nut Mfg. Lot Number(s): Nut-41465-S-20958990
Washer Mfg. Lot Number(s): Wash-244757 / 46541
Bolt Specification: ASTM A325
Bolt Length(s): 2 1/2"
Nut Specification: ASTM A563
Washer Specification: ASTM F436-1
Finish: ASTM A153, ASTM F2329
Diameter/Size: 3/4"
Bolt Mfg. Lot Number: Bolt-G11604
Rocap Test Requirement(s): Max. Torque
Lubricant Requirements(s):
Washer Inner Diameter(s):
Test Results
Test 1 of 8
DIME Test ID: 2026-01-09-4-1
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 01/27/2026
Date Tested: 01/27/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
G11604
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
.75 in
|
|
Bolt Length
|
2.5 in
|
|
Pitch Diameter
|
0.6880 in
|
|
Pitch Diameter 2nd
|
no data in
|
Test 2 of 8
DIME Test ID: 2026-01-09-4-2
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/27/2026
Date Tested: 01/27/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
G11604
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
.75 in
|
|
Bolt Length
|
2.5 in
|
|
Measurement Average
|
2.9 mils
|
Test 3 of 8
DIME Test ID: 2026-01-09-4-3
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/27/2026
Date Tested: 01/27/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
41465-S-20958990
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.3 mils
|
Test 4 of 8
DIME Test ID: 2026-01-09-4-4
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/27/2026
Date Tested: 01/27/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
244757
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
8 mils
|
Test 5 of 8
DIME Test ID: 2026-01-09-4-5
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/27/2026
Date Tested: 01/27/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
G11604
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
.75 in
|
|
Bolt Length
|
2.5 in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
29
|
|
Spacing
|
Ok
|
Test 6 of 8
DIME Test ID: 2026-01-09-4-6
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/27/2026
Date Tested: 01/27/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
41465-S-20958990
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
26
|
|
Spacing
|
Ok
|
Test 7 of 8
DIME Test ID: 2026-01-09-4-7
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/27/2026
Date Tested: 01/27/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
244757
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
34
|
|
Spacing
|
Ok
|
Test 8 of 8
DIME Test ID: 2026-01-09-4-8
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 01/27/2026
Date Tested: 01/27/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Bolt Samples
|
1
|
| Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | | 1A | G11604 | .75 | 45540 | 0000 | 0000 | A325 | Kleinfelder |
| |
|
UTM
|
NA
|
|
Temperature
|
0 f
|