Project Information
Project ID: 1000501 DEA: 081J6104 EFIS: 0818000102
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-215-40.5/42.7
Work Description: INDIVIDUAL SLAB REPLACEMENT (RSC), RHMA, AND REPLACE BASE.
Location Description: RIVERSIDE COUNTY IN RIVERSIDE FROM 0.8 MILE SOUTH OF ROUTE 60/91 SEPARATION TO 0.4 MILE SOUTH OF MARTIN LUTHER KING BOULEVARD UNDERCROSSING
Contractor Name: FBD VANGUARD CONSTRUCTION, INC.
Contractor Address: 550 Greenville Rd., Livermore, CA
Resident Engineer: Mahfual Alam Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2026-01-07-17
TL Number from the TL Form: 1081-0107
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 01/07/2026
Date that the sample was received by the laboratory/organization performing the testing: 01/08/2026
The quantity of what the sample constitutes: 3
A brief description of the sample: 6x12
From where was the sample collected: Job Site
Laboratory sample identification: 1081-0107
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vanguard
Material Information
The concrete mix design number: -
The truck number from where the sample was collected: 2
The batch plant ticket number from where the sample was collected: na
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: 215 SB
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
Test Results
Test 1 of 1
DIME Test ID: 2026-01-07-17-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617 - Sulfur Mortar Cap Cured in accordance with ASTM C511
Verified Date: 01/21/2026
Date Tested: 01/14/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Cross sectional area of cylinder 1
|
28.56 in^2
|
|
Cross sectional area of cylinder 2
|
28.46 in^2
|
|
Cross sectional area of cylinder 3
|
28.56 in^2
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Compressive strength (to nearest 10 psi)
|
8300 psi
|
|
Average diameter of cylinder 1
|
6.03 in
|
|
Average diameter of cylinder 2
|
6.02 in
|
|
Compressive strength of cylinder 1
|
8166.1 psi
|
|
Compressive strength of cylinder 2
|
8178.8 psi
|
|
Average diameter of cylinder 3
|
6.03 in
|
|
Compressive strength of cylinder 3
|
8566 psi
|
|
Maximum load on cylinder 1
|
233225 lb
|
|
Maximum load on cylinder 2
|
232770 lb
|
|
Maximum load on cylinder 3
|
244645 lb
|
|
Type of fracture pattern of cylinder 1
|
3
|
|
Type of fracture pattern of cylinder 2
|
3
|
|
Type of fracture pattern of cylinder 3
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
7 days
|