Print Report | Back to Sample Detail

Sample Record for 2025-12-23-6

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995493 DEA: 081G6704 EFIS: 0816000049 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-79-5.4/11.4
Work Description: HOT MIX ASPHALT, SOIL NAIL, STRUCTURAL CONCRETE AND ROADWAY EXC.
Location Description: RIVERSIDE COUNTY NEAR TEMECULA FROM 0.4 MILE SOUTH OF SAGE ROAD TO 1.1 MILES SOUTH OF PAUBA ROAD
Contractor Name: ORTIZ ENTERPRISES, INC.
Contractor Address: 6 CUSHING STE 200, IRVINE, CA 92618
Resident Engineer: Osama Abdalla Structure Rep.: Arnel Vega

Sample Information

DIME Sample ID: 2025-12-23-6
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 12/23/2025
Date that the sample was received by the laboratory/organization performing the testing: 12/24/2025
The quantity of what the sample constitutes: 8
A brief description of the sample: 4x8
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: np

Material Information

The concrete mix design number: 5236125A
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: np
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: RW #349 stem
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test

DIME Test ID: 2025-12-23-6-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 01/12/2026
Date Tested: 12/30/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Apparent mass of submerged cylinder 1 no data0 lb
Average diameter of cylinder 1 4.01 in
Average diameter of cylinder 2 4.01 in
Cross sectional area of cylinder 1 12.63 in^2
Cross sectional area of cylinder 2 12.63 in^2
Compressive strength (to nearest 10 psi) 4080 psi
Maximum load on cylinder 1 53170 lb
Maximum load on cylinder 2 49700 lb
Compressive strength of cylinder 1 4210.0 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 3940.0 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 7 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data

Test

DIME Test ID: 2025-12-23-6-2
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 01/21/2026
Date Tested: 01/06/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Apparent mass of submerged cylinder 1 no data0 lb
Average diameter of cylinder 1 4.01 in
Average diameter of cylinder 2 4.01 in
Cross sectional area of cylinder 1 12.63 in^2
Cross sectional area of cylinder 2 12.63 in^2
Compressive strength (to nearest 10 psi) 4910 psi
Maximum load on cylinder 1 61970 lb
Maximum load on cylinder 2 61860 lb
Compressive strength of cylinder 1 4910.0 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 4900.0 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 14 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data

Test

DIME Test ID: 2025-12-23-6-3
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 01/21/2026
Date Tested: 01/20/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Apparent mass of submerged cylinder 1 no data0 lb
Average diameter of cylinder 1 4.01 in
Average diameter of cylinder 2 4.02 in
Cross sectional area of cylinder 1 12.63 in^2
Cross sectional area of cylinder 2 12.69 in^2
Compressive strength (to nearest 10 psi) 5880 psi
Maximum load on cylinder 1 75660 lb
Maximum load on cylinder 2 73170 lb
Compressive strength of cylinder 1 5990.0 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 5770.0 psi
Type of fracture pattern of cylinder 2 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 28 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data