Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 88887 DEA: PC-Barrier-STOCK EFIS: PC-Barrier-STOCK
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for precast barrier rail stock material.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2025-12-08-42
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: Precast Concrete
Sample Taken Date: 12/08/2025
Date that the sample was received by the laboratory/organization performing the testing: 12/09/2025
The quantity of what the sample constitutes: 50 CY
A brief description of the sample: Three 4"x8" Cylinders
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: ProCast Products, Sunol
The concrete mix design number: 6381219
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 3006812
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete Sample from Wheelbarrow
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2025-12-08-42-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 01/05/2026
Date Tested: 01/05/2026
Submitted By Organization: CT HQ - QASI Bay Area Field Office
Organization Address: 690 Walnut Avenue, Suite 150,
Organization City: Vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: maged.g.armanuse@dot.ca.gov
Organization Phone: (916) 284-6784
General Comments for this Test: 5000 psi required at 28-days; 6760 psi reported QC 28-day average
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Apparent mass of submerged cylinder 1
|
1 lb
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
7180 psi
|
|
Maximum load on cylinder 1
|
87645 lb
|
|
Maximum load on cylinder 2
|
92310 lb
|
|
Maximum load on cylinder 3
|
91015 lb
|
|
Compressive strength of cylinder 1
|
6970.0 psi
|
|
Type of fracture pattern of cylinder 1
|
5
|
|
Compressive strength of cylinder 2
|
7340.0 psi
|
|
Compressive strength of cylinder 3
|
7240 psi
|
|
Type of fracture pattern of cylinder 2
|
5
|
|
Type of fracture pattern of cylinder 3
|
5
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
28 days
|
|
Age of specimen in hours
|
no data0 hours
|
|
Serial number of delivery ticket, if available
|
no data
|