Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000731 DEA: 042Q4404 EFIS: 0419000013
QA Service Level: 1
DIST-CO-RTE-PM: 04-SON-121-6.5,8.4
Work Description: REMOVE BR AND AC SURF, CONSTRUCT BR DECK, RAILING AND POLYESTER CONC.
Location Description: SONOMA COUNTY NEAR SONOMA AT YELLOW CREEK BRIDGE AND AT ARROYO SECO BRIDGE
Contractor Name: GORDON N. BALL, INC.
Contractor Address: Unknown
Resident Engineer: Fabio La Serna Structure Rep.: Jeremy Light
DIME Sample ID: 2025-12-23-4
TL Number from the TL Form:
Sample Submitted By Organization: CT SC - 3672 - Novato Field Office
Sample Organization Contact: (916) 621-8033
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 12/23/2025
Date that the sample was received by the laboratory/organization performing the testing: 12/23/2025
The quantity of what the sample constitutes: 5 CY
A brief description of the sample: 3 4x8 cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier: 20-0021
Structure name: YELLOW CREEK BRIDGE Deck northbound
The fabricator/manufacturer/facility name: Shamrock Materials Inc
The concrete mix design number: H7511503
The truck number from where the sample was collected: 2434
The batch plant ticket number from where the sample was collected: 424515
Concrete batch plant: 138
The fabricator/manufacturer designation for the sample: Shamrock Materials
A detailed description of where the material sample was collected: Back of Truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2025-12-23-4-1
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Submitted By Organization: CT SC - 3672 - Novato Field Office
Organization Address: 384 Bel Marin Keys Boulevard, Suite 200,
Organization City: Novato
Organization State: CA
Organization Zipcode: 94949
Organization Email: josh.velono@dot.ca.gov
Organization Phone: (916) 621-8033
Data has not been verified.
DIME Test ID: 2025-12-23-4-2
Test Method: ASTM C143-15a: Standard Test Method for Slump of Hydraulic-Cement Concrete
Submitted By Organization: CT SC - 3672 - Novato Field Office
Organization Address: 384 Bel Marin Keys Boulevard, Suite 200,
Organization City: Novato
Organization State: CA
Organization Zipcode: 94949
Organization Email: josh.velono@dot.ca.gov
Organization Phone: (916) 621-8033
Data has not been verified.
DIME Test ID: 2025-12-23-4-3
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 12/26/2025
Date Tested: 12/26/2025
Submitted By Organization: CT HQ - Vallejo Field Laboratory
Organization Address: 690 Walnut,
Organization City: vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: yannick.aranas@dot.ca.gov
Organization Phone: (916) 639-4315
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Average diameter of cylinder 1
|
4.01 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.63 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
5590 psi
|
|
Maximum load on cylinder 1
|
68185 lb
|
|
Maximum load on cylinder 2
|
70055 lb
|
|
Maximum load on cylinder 3
|
72960 lb
|
|
Compressive strength of cylinder 1
|
5398.7 psi
|
|
Type of fracture pattern of cylinder 1
|
5
|
|
Compressive strength of cylinder 2
|
5573.2 psi
|
|
Compressive strength of cylinder 3
|
5804.3 psi
|
|
Type of fracture pattern of cylinder 2
|
3
|
|
Type of fracture pattern of cylinder 3
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
3 days
|
|
Age of specimen in hours
|
no data
|
DIME Test ID: 2025-12-23-4-4
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 01/23/2026
Date Tested: 01/20/2026
Submitted By Organization: Quality Assurance Engineering, Inc dba Consolidated Engineering Laboratories
Organization Address: 690 Walnut,
Organization City: vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: yannick.aranas@dot.ca.gov
Organization Phone: (916) 639-4315
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
9260 psi
|
|
Maximum load on cylinder 1
|
116600 lb
|
|
Maximum load on cylinder 2
|
115980 lb
|
|
Maximum load on cylinder 3
|
116430 lb
|
|
Compressive strength of cylinder 1
|
9276.1 psi
|
|
Type of fracture pattern of cylinder 1
|
3
|
|
Compressive strength of cylinder 2
|
9226.7 psi
|
|
Compressive strength of cylinder 3
|
9262.5 psi
|
|
Type of fracture pattern of cylinder 2
|
3
|
|
Type of fracture pattern of cylinder 3
|
3
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
28 days
|
|
Age of specimen in hours
|
no data
|