Sample Record for 2025-12-18-42
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 1000510 DEA: 060W79U4 EFIS: 0622000189
QA Service Level: 1
DIST-CO-RTE-PM: 06-KER,TUL-99-56.4/57.6,0.0/13.5
Work Description: RDWY EXC, HMA, AGGREGATE BASE, CRCP, SIGN STR, AND STR EXC.
Location Description: KERN AND TULARE COUNTIES IN AND NEAR DELANO FROM 0.2 MILE SOUTH OF CECIL AVENUE OVERCROSSING TO 0.7 MILE NORTH OF AVENUE 100 OVERCROSSING
Contractor Name: Security Paving Company, Inc.
Contractor Address: 2915 Fairhaven Drive, Bakersfield, CA 93308
Resident Engineer: Jake Garcia Structure Rep.: Raman Guraya
Sample Information
DIME Sample ID: 2025-12-18-42
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Millbrook Field Laboratory
Sample Organization Contact: (559) 341-3953
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 12/18/2025
Date that the sample was received by the laboratory/organization performing the testing: 12/19/2025
The quantity of what the sample constitutes: 19
A brief description of the sample: Soundwall 4 CIDH Piles
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Calportland Tulare
Material Information
The concrete mix design number: 163457D
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 270434
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Pile 72 to 81
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
Test Results
Test 1 of 1
DIME Test ID: 2025-12-18-42-5
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 01/15/2026
Date Tested: 01/15/2026
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 1352 W. Olive Ave,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93728
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 341-3953
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
4380 psi
|
|
Maximum load on cylinder 1
|
54840 lb
|
|
Maximum load on cylinder 2
|
54540 lb
|
|
Maximum load on cylinder 3
|
55640 lb
|
|
Compressive strength of cylinder 1
|
4362.8 psi
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Compressive strength of cylinder 2
|
4338.9 psi
|
|
Compressive strength of cylinder 3
|
4426.4 psi
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Type of fracture pattern of cylinder 3
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
28 days
|
|
Age of specimen in hours
|
no data0 hours
|
Tests Assigned to this Sample
| DIME Test ID | Test Method | Assigned Date | Test Date | Assigned By | Assigned Lab | Test Comments | Assigned To |
| 2025-12-18-42-1 | CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders | 12/19/2025 | Not scheduled | Bandy Ahmed | CT D06 - Millbrook Field Laboratory | | |
| 2025-12-18-42-2 | CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders | 12/19/2025 | Not scheduled | Bandy Ahmed | CT D06 - Millbrook Field Laboratory | Required strenght 3600 psi @ 28 days | |
| 2025-12-18-42-3 | CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders | 12/19/2025 | Not scheduled | Bandy Ahmed | CT D06 - Millbrook Field Laboratory | | |
| 2025-12-18-42-4 | CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders | 12/19/2025 | Not scheduled | Bandy Ahmed | CT D06 - Millbrook Field Laboratory | Required strenght 3600 psi @ 28 days | |
152657152658152659152660