Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000365 DEA: 033H9014 EFIS: 0323000075
QA Service Level: 1
DIST-CO-RTE-PM: 03-SOL,YOL-50,80,113-Var
Work Description: HMA, RHMA, SIGN STRUCTURE, CAMERA SYSTEMS, & FO CABLE SYSTEMS.
Location Description: SOLANO AND YOLO COUNTIES AT VARIOUS LOCATIONS
Contractor Name: DESILVA GATES CONSTRUCTION, LLC
Contractor Address: 3855 North Freeway Boulevard, Suite 100, Sacramento, CA 95834
Resident Engineer: Joseph Wild Structure Rep.: Michael Charak
DIME Sample ID: 2025-12-02-41
TL Number from the TL Form:
Sample Submitted By Organization: Blackburn Consulting
Sample Organization Contact: (916) 375-8706
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 12/02/2025
Date that the sample was received by the laboratory/organization performing the testing: 12/17/2025
The quantity of what the sample constitutes: 2 Boxes
A brief description of the sample: 3/4" WMA-SP w/ RAP
From where was the sample collected: Source
Laboratory sample identification: 6102
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Teichert Woodland
DIME Test ID: 2025-12-02-41-1
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 01/05/2026
Date Tested: 12/18/2025
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
2920.9 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5070.2 g
|
|
Corrected Asphalt Binder Content
|
4.9 %
|
|
Mass of HMA Sample prior to ignition
|
2149.3 g
|
|
Mass Loss
|
126.7 g
|
|
Mass of aggregate remaining after ignition
|
2022.6 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.85 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.14 %
|
|
Test Temperature
|
482 C
|