Project Information

Project ID: 1000117 DEA: 020J0104 EFIS: 0219000044 QA Service Level: 1
DIST-CO-RTE-PM: 02-TEH-99-4.2/4.8
Work Description: PLACE HMA, CCTV TOWER AND INSTALL LIGHTING SYSTEM.
Location Description: TEHAMA COUNTY ABOUT 7.0 MILES SOUTH OF LOS MOLINOS FROM 0.3 MILE SOUTH OF SOUTH AVENUE TO 0.6 MILE SOUTH OF VINA ROAD
Contractor Name: BALDWIN CONTRACTING COMPANY, INC. DBA KNIFE RIVER CONSTRUCTION
Contractor Address: 1764 Skyway, Chico, CA 95928
Resident Engineer: Edward Worden Structure Rep.: Chris Brace

Sample Information

DIME Sample ID: 2025-06-10-130
TL Number from the TL Form: TL-502-165621
Sample Submitted By Organization: CT D02 - Red Bluff Field Laboratory
Sample Organization Contact: (530) 605-5865
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 06/10/2025
Date that the sample was received by the laboratory/organization performing the testing: 06/11/2025
The quantity of what the sample constitutes: 6 4x8 Cylinders
A brief description of the sample: Concrete Test Samples
From where was the sample collected: Job Site
Laboratory sample identification: 003
Structure unique identifier:
Structure name: Box Culvert
The fabricator/manufacturer/facility name: Mathews Ready Mix

Material Information

The concrete mix design number: 06316P15
The truck number from where the sample was collected: 0727
The batch plant ticket number from where the sample was collected: 17034940
Concrete batch plant: 1619 Chico
The fabricator/manufacturer designation for the sample: Mathews order 2030
A detailed description of where the material sample was collected: concrete truck into wheelbarrow.
Where the material sample would have been placed if not sampled: Box Culvert
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2025-06-10-130-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 12/16/2025
Date Tested: 07/08/2025
Submitted By Organization: CT D02 - Red Bluff Field Laboratory
Organization Address: 13700 highway 36E ,
Organization City: Red Bluff
Organization State: CA
Organization Zipcode: 96080
Organization Email: brandon.white@dot.ca.gov
Organization Phone: (530) 605-5865
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Apparent mass of submerged cylinder 1 no data0 lb
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 4930 psi
Maximum load on cylinder 1 60050 lb
Maximum load on cylinder 2 63130 lb
Maximum load on cylinder 3 62670 lb
Compressive strength of cylinder 1 4780.0 psi
Type of fracture pattern of cylinder 1 4
Compressive strength of cylinder 2 5020.0 psi
Compressive strength of cylinder 3 4990 psi
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 4
Comment on any defect in either specimen or caps (Max 250 Characters) Bonded caps
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available 17034940