Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 995262 DEA: 041Q4604 EFIS: 0418000279
QA Service Level: 1
DIST-CO-RTE-PM: 04-SCL-280-0/2.7
Work Description: RHMA-G SURFACING AND CONSTRUCT BRIDGE APPROACH.
Location Description: SANTA CLARA COUNTY IN SAN JOSE FROM ROUTE 280/680/101 SEPARATION TO 0.2 MILE WEST OF BIRD AVENUE OVERCROSSING
Contractor Name: O.C. JONES & SONS, INC.
Contractor Address: 1520 4th Street, Berkeley, CA 94710
Resident Engineer: Nim Patel Structure Rep.: Unknown
DIME Sample ID: 2025-08-25-124
TL Number from the TL Form: SJ-082525-2
Sample Submitted By Organization: CT D04 - San Jose Construction Field Laboratory
Sample Organization Contact: (510) 385-8171
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/25/2025
Date that the sample was received by the laboratory/organization performing the testing: 08/26/2025
The quantity of what the sample constitutes: 750-1500 Tons
A brief description of the sample: 3/4"RHMA-G
From where was the sample collected: Source
Laboratory sample identification: SJ-082525-T308-L1SL5
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Marietta Sunol Drier Drum Plant
DIME Test ID: 2025-08-25-124-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 12/18/2025
Date Tested: 09/03/2025
Submitted By Organization: CT D04 - San Jose Construction Field Laboratory
Organization Address: 1007 Knox Avenue,
Organization City: San Jose
Organization State: CA
Organization Zipcode: 95122
Organization Email: fernando.vega@dot.ca.gov
Organization Phone: (510) 385-8171
General Comments for this Test: LOT 1 SUBLOT 5
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of HMA Sample prior to ignition
|
2183 g
|
|
Corrected Asphalt Binder Content
|
7.47 %
|
|
Mass Loss
|
180.1 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.62 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.16 %
|
|
Test Temperature
|
538 C
|