Print Report | Back to Sample Detail

Sample Record for 2025-12-12-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000004 DEA: 033H5604 EFIS: 0318000014 QA Service Level: 1
DIST-CO-RTE-PM: 03-PLA,NEV-20,80-VAR
Work Description: STRUCTURAL CONC, BAR REINFORCING STEEL, BRIDGE REMOVAL, HMA, AND JPCP.
Location Description: PLACER AND NEVADA COUNTIES NEAR CISCO GROVE ON ROUTE 80 FROM 0.4 MILE WEST OF LAKE VALLEY OVERCROSSING TO 0.9 MILE EAST OF YUBA PASS SEPARATION AND OVERHEAD AND ON ROUTE 20 AT YUBA PASS SEPARATION AND OVERHEAD
Contractor Name: FLATIRON WEST INC.
Contractor Address: 1200 Concord Ave Suite 465, Concord, CA 94520
Resident Engineer: Tad Sampson Structure Rep.: James 'Jimmer' Ross

Sample Information

DIME Sample ID: 2025-12-12-1
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 12/12/2025
Date that the sample was received by the laboratory/organization performing the testing: 12/22/2025
The quantity of what the sample constitutes: 1,460 hoops
A brief description of the sample: #7 6'-7"dia. welded hoop
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CMC Rebar

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Ultimate
Rebar Heat Number(s): 9010497, 9010078
Hoop Manufacturer Lot Number(s): 17, 23
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Size: #7
Diameter of Hoop: 6'-7"
Epoxy Coated: No
Epoxy Coating Color: NA
Rebar Manufacturer: CMC Rebar
Welding Company: CMC Rebar San Bernardino
Coating Standards: Uncoated
Weld Type: Flash Welded

Test Results

Test 1 of 1

DIME Test ID: 2025-12-12-1-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 01/15/2026
Date Tested: 01/15/2026
Submitted By Organization: Atlas - Oakland
Organization Address: 534 23rd Avenue,
Organization City: Oakland
Organization State: CA
Organization Zipcode: 94606
Organization Email: guillermo.baltazar@oneatlas.com
Organization Phone: (510) 434-3018
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 8
SampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11770.605721095350ok neckingAtlas
21770.605697094950ok neckingAtlas
31770.605754095900ok neckingAtlas
41770.605751095850ok neckingAtlas
12370.605704095067ok neckingAtlas
22370.605688094800ok neckingAtlas
32370.605703095050ok neckingAtlas
42370.605691094850ok neckingAtlas
UTM NA
Temperature 0 f