Print Report | Back to Sample Detail

Sample Record for 2025-12-06-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995228 DEA: 07347904 EFIS: 0718000123 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-405-31.2/41.4
Work Description: COLD PLANE, PLACE HMA, RHMA, JPCP, ISR, & REPLACE BRIDGE SLABS.
Location Description: LOS ANGELES FROM WILSHIRE BOULEVARD UNDERCROSSING TO VICTORY BOULEVARD UNDERCROSSING
Contractor Name: RASMUSSEN/VANGUARD
Contractor Address: 28548 Livingston Ave, Valencia , CA,91355-4171
Resident Engineer: Denrick Bautista Structure Rep.: Gon Choi

Sample Information

DIME Sample ID: 2025-12-06-3
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 12/06/2025
Date that the sample was received by the laboratory/organization performing the testing: 12/11/2025
The quantity of what the sample constitutes: 5 bags comb agg, 1 bag RAP
A brief description of the sample: PSUE 3/4" HMA-A-SP R25 0.75% LAS
From where was the sample collected: Manufacturer
Laboratory sample identification: 0690A-25
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Irwindale Fish Canyon/ SJR/ Ingevity/ Morlife

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-19-0016, 91-19-0035
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Belt Cut at Vulcan Irwindale Plant
Where the material sample would have been placed if not sampled: Asphalt Paving
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number: 220200M IRW SJR
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2025-12-06-3-1AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)12/11/2025Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory
2025-12-06-3-2AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)12/11/2025Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory
2025-12-06-3-3AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)12/11/2025Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory
2025-12-06-3-4AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)12/11/2025Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory
2025-12-06-3-5AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)12/11/2025Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory
2025-12-06-3-6AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)12/11/2025Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory
2025-12-06-3-7AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)12/11/2025Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory
2025-12-06-3-8ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)12/11/2025Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory
2025-12-06-3-9CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates12/11/2025Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory
2025-12-06-3-10CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates12/11/2025Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory