Print Report | Back to Sample Detail

Sample Record for 2025-05-21-136

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000698 DEA: 024H0704 EFIS: 0218000074 QA Service Level: 1
DIST-CO-RTE-PM: 02-LAS-139-0.74/11.0
Work Description: PLACE HMA (TYPE A), TRAFFIC CONTROL SYSTEM, TRAFFIC STRIPE, RDWY EXC.
Location Description: LASSEN COUNTY NEAR SUSANVILLE FROM 0.1 MILE NORTH OF CHESTNUT STREET TO 2.6 MILES SOUTH OF HORSE LAKE ROAD
Contractor Name: HAT CREEK CONSTRUCTION & MATERIALS, INC.
Contractor Address: Unknown
Resident Engineer: Daniel Gibbs Structure Rep.: Tooraj Yegan

Sample Information

DIME Sample ID: 2025-05-21-136
TL Number from the TL Form:
Sample Submitted By Organization: CT D02 - Red Bluff Field Laboratory
Sample Organization Contact: (530) 605-5865
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 05/21/2025
Date that the sample was received by the laboratory/organization performing the testing: 05/22/2025
The quantity of what the sample constitutes: 6 Cylinders 4x8
A brief description of the sample: Concrete Test Samples
From where was the sample collected: Job Site
Laboratory sample identification: TL-502-263596-001
Structure unique identifier:
Structure name: Barrier Slab
The fabricator/manufacturer/facility name: White Cap Ready Mix

Material Information

The concrete mix design number: WC 688
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: C-18552
Concrete batch plant: Portolla
The fabricator/manufacturer designation for the sample: White Cap Ready Mix
A detailed description of where the material sample was collected: Mix Truck
Where the material sample would have been placed if not sampled: Barrier wall
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2025-05-21-136-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 12/11/2025
Date Tested: 06/18/2025
Submitted By Organization: CT D02 - Red Bluff Field Laboratory
Organization Address: 13700 highway 36E ,
Organization City: Red Bluff
Organization State: CA
Organization Zipcode: 96080
Organization Email: brandon.white@dot.ca.gov
Organization Phone: (530) 605-5865
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Apparent mass of submerged cylinder 1 no data0 lb
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 6490 psi
Maximum load on cylinder 1 81300 lb
Maximum load on cylinder 2 82280 lb
Maximum load on cylinder 3 81060 lb
Compressive strength of cylinder 1 6470.0 psi
Type of fracture pattern of cylinder 1 4
Compressive strength of cylinder 2 6550.0 psi
Compressive strength of cylinder 3 6450 psi
Type of fracture pattern of cylinder 2 4
Type of fracture pattern of cylinder 3 4
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available C-18552