Sample Record for 2025-11-05-90
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 214649 DEA: 07316004 EFIS: 0715000194
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-14-60.70
Work Description: REHABILITATION FOR THE ON/OFF RAMPS AND ADJACENT SHOULDERS. UPGRADING METAL BEAM GUARDRAILS, AC DIKES, SIGN PANELS, CURB RAMPS, TRAFFIC LOOPS DETECTORS, AND SOME OTHER HIGHWAY APPURTENANCES.
Location Description: ROUTE 14 FROM PALMDALE BLVD TO KERN COUNTRY LINE.
Contractor Name: Guy F. Atkinson Construction LLC
Contractor Address: 18201 Von Karman Ave, Suite 800, Irvine, CA 92612
Resident Engineer: James Shih Structure Rep.: Hossein Sabbagh
Sample Information
DIME Sample ID: 2025-11-05-90
TL Number from the TL Form:
Sample Submitted By Organization: Kleinfelder, Incorporated - Los Angeles
Sample Organization Contact: (909) 833-5780
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 11/05/2025
Date that the sample was received by the laboratory/organization performing the testing: 11/06/2025
The quantity of what the sample constitutes: 40 CY
A brief description of the sample: LCB
From where was the sample collected: Job Site
Laboratory sample identification: 25-3666
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CalPortland
Material Information
The concrete mix design number: 12622-LCB-1
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 4
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Truck #24
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
Test Results
Test 1 of 1
DIME Test ID: 2025-11-05-90-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 11/24/2025
Date Tested: 11/12/2025
Submitted By Organization: Kleinfelder, Incorporated - Los Angeles
Organization Address: 620 South Magnolia Avenue, Building G,
Organization City: Ontario
Organization State: CA
Organization Zipcode: 91762
Organization Email: mdorsch@kleinfelder.com
Organization Phone: (909) 833-5780
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
2
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Average diameter of cylinder 1
|
5.97 in
|
|
Average diameter of cylinder 2
|
5.97 in
|
|
Cross sectional area of cylinder 1
|
27.99 in^2
|
|
Cross sectional area of cylinder 2
|
27.99 in^2
|
|
Compressive strength (to nearest 10 psi)
|
920 psi
|
|
Maximum load on cylinder 1
|
26563 lb
|
|
Maximum load on cylinder 2
|
24901 lb
|
|
Type of fracture pattern of cylinder 1
|
5
|
|
Type of fracture pattern of cylinder 2
|
5
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Age of specimen
|
7 days
|
|
Age of specimen in hours
|
no data0 hours
|