Sample Record for 2025-06-10-126
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 1000365 DEA: 033H9014 EFIS: 0323000075
QA Service Level: 1
DIST-CO-RTE-PM: 03-SOL,YOL-50,80,113-Var
Work Description: HMA, RHMA, SIGN STRUCTURE, CAMERA SYSTEMS, & FO CABLE SYSTEMS.
Location Description: SOLANO AND YOLO COUNTIES AT VARIOUS LOCATIONS
Contractor Name: DESILVA GATES CONSTRUCTION, LLC
Contractor Address: 3855 North Freeway Boulevard, Suite 100, Sacramento, CA 95834
Resident Engineer: Joseph Wild Structure Rep.: Michael Charak
Sample Information
DIME Sample ID: 2025-06-10-126
TL Number from the TL Form:
Sample Submitted By Organization: G3 Quality, Incorporated - Cerritos
Sample Organization Contact: (562) 321-9840
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 06/10/2025
Date that the sample was received by the laboratory/organization performing the testing: 06/11/2025
The quantity of what the sample constitutes: 4
A brief description of the sample: 4x8 Cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 1626827 Set 1
Structure unique identifier:
Structure name: Sign C1, STA 139+00
The fabricator/manufacturer/facility name: Cemex West Sacramento
Material Information
The concrete mix design number: 16286827
The truck number from where the sample was collected: Load 1
The batch plant ticket number from where the sample was collected: 31637918
Concrete batch plant: Cemex
The fabricator/manufacturer designation for the sample: Set 1
A detailed description of where the material sample was collected: Sign C1, STA 139+00
Where the material sample would have been placed if not sampled: Sign C1
From Lot No.: 1
Bag Lot No.: 1
Test Results
Test 1 of 5
DIME Test ID: 2025-06-10-126-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 11/21/2025
Date Tested: 06/24/2025
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
1
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Compressive strength of cylinder (to nearest 10 psi)
|
6950 psi
|
|
Maximum load on cylinder 1
|
87300 lb
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Age of specimen
|
14 days
|
|
Age of specimen in hours
|
no data0 hours
|
Test 2 of 5
DIME Test ID: 2025-06-10-126-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 11/21/2025
Date Tested: 07/08/2025
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
8970 psi
|
|
Maximum load on cylinder 1
|
113680 lb
|
|
Maximum load on cylinder 2
|
111800 lb
|
|
Maximum load on cylinder 3
|
112410 lb
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Type of fracture pattern of cylinder 2
|
3
|
|
Type of fracture pattern of cylinder 3
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
28 days
|
|
Age of specimen in hours
|
no data0 hours
|
Test 3 of 5
DIME Test ID: 2025-06-10-126-3
Test Method: CTM 518-June 2010: Method of Test for Unit Weight of Fresh Concrete
Verified Date: 11/21/2025
Date Tested: 06/10/2025
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit weight of the concrete
|
143.64 lb/ft^3
|
|
Cement content
|
no data0 lb/yd^3
|
Test 4 of 5
DIME Test ID: 2025-06-10-126-4
Test Method: CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 11/21/2025
Date Tested: 06/10/2025
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Test 5 of 5
DIME Test ID: 2025-06-10-126-5
Test Method: CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement Concrete
Verified Date: 11/21/2025
Date Tested: 06/10/2025
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified: