Print Report | Back to Sample Detail

Sample Record for 2025-10-23-57

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995119 DEA: 034H6004 EFIS: 0319000004 QA Service Level: 1
DIST-CO-RTE-PM: 03-PLA-49-R8.7/R10.6
Work Description: CONC BARRIER, JPCP, HMA, RDWY EXC, RCP AND LIGHTING.
Location Description: PLACER COUNTY NEAR AUBURN FROM 0.3 MILE SOUTH OF LORENSEN ROAD/FLORENCE LANE TO 0.4 MILE NORTH OF LONE STAR ROAD
Contractor Name: DESILVA GATES CONSTRUCTION, LLC
Contractor Address: Unknown
Resident Engineer: Jeff Johnson Structure Rep.: Asia Al Maliki

Sample Information

DIME Sample ID: 2025-10-23-57
TL Number from the TL Form:
Sample Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Sample Organization Contact: (530) 741-4238
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 10/23/2025
Date that the sample was received by the laboratory/organization performing the testing: 11/06/2025
The quantity of what the sample constitutes: 2 Boxes
A brief description of the sample: 1/2" RWMA-O
From where was the sample collected: Source
Laboratory sample identification: Daily 25-254
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Desilva Gates-Marysville

Material Information

HMA Type: OGFC
HMA Grading: 1/2 inch
Lot number: 1
Sublot number: 5
HMA Mix Number: MD 6653
Binder content (%): 7.4
Virgin binder PG:
Design binder PG: PG 64-16
Binder Supplier: Valero
RAP content (%): 0
WMA Additives: Yes
Antistrip type: Evotherm M1

Test Results

Test 1 of 1

DIME Test ID: 2025-10-23-57-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 11/21/2025
Date Tested: 11/20/2025
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test: R1 OBC 7.4
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 1639.7 g
Corrected Asphalt Binder Content 7.03 %
Mass Loss 120.9 g
Correction Factor (Percent by mass of HMA Specimen) 0.34 %
Moisture Content no data0 %
Temperature Compensation Factor 0.02 %
Test Temperature 538 C