Print Report | Back to Sample Detail

Sample Record for 2025-09-25-95

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001605 DEA: 114B0044 EFIS: 1122000173 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-5-54-9.5,0.0/6.4
Work Description: Construct Middle Mile Broadband Network.
Location Description: IN SAN DIEGO COUNTY IN AND NEAR SAN DIEGO, NATIONAL CITY, AND CHULA VISTA ON ROUTE 5 AT 0.1 MILE NORTH OF SWEETWATER RIVER BRIDGE AND ON ROUTE 54 FROM ROUTE 5/54 SEPARATION TO 0.4 MILE EAST OF SWEETWATER ROAD UNDERCROSSING
Contractor Name: Griffith Company Henkels & McCoy
Contractor Address: 3050 East Birch Street, Brea, CA 92821
Resident Engineer: Alfredo Hernandez-Medina Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2025-09-25-95
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 09/25/2025
Date that the sample was received by the laboratory/organization performing the testing: 09/26/2025
The quantity of what the sample constitutes: 2 boxes
A brief description of the sample: Normal Production
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Otay

Material Information

HMA Type: Type A HMA
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number: 320200 Otay Val
Binder content (%): 4.9
Virgin binder PG: PG58-16
Design binder PG: PG 64-16
Binder Supplier: Valero
RAP content (%): 22
WMA Additives: No
Antistrip type: No

Test Results

Test 1 of 2

DIME Test ID: 2025-09-25-95-1
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 12/02/2025
Date Tested: 11/18/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 4026 g
Mass of the specimen and specimen basket assembly prior to ignition 5551.6 g
Corrected Asphalt Binder Content 5.3 %
Mass of HMA Sample prior to ignition 1525.6 g
Mass Loss 89.9 g
Mass of aggregate remaining after ignition 1435.7 g
Correction Factor (Percent by mass of HMA Specimen) 0.59 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C

Test 2 of 2

DIME Test ID: 2025-09-25-95-2
Test Method: AASHTO T209-25: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 12/02/2025
Date Tested: 11/20/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 1 7475.6 grams
Mass of oven-dry sample in air for Sample 1 1520.8 grams
Mass of container filled with the sample and water for Sample 1 8390.1 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.508
Theoretical maximum density at 25°C (77°F) 156.1 lb/ft^3