Print Report | Back to Sample Detail

Sample Record for 2025-05-28-127

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000402 DEA: 11430384 EFIS: 1118000114 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-805-23.7/28.5
Work Description: REPLACE DRAINAGE, CONCRETE PAVEMENT, AND MODIFY ELECTRICAL SYSTEMS.
Location Description: SAN DIEGO COUNTY IN SAN DIEGO FROM 0.1 MILE NORTH OF ROUTE 805/52 SEPARATION TO ROUTE 5/805 SEPARATION
Contractor Name: HAZARD CONSTRUCTION ENGR, LLC
Contractor Address: 10529 VINE STREET, LAKESIDE, CA 92040
Resident Engineer: Karl Hartline Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2025-05-28-127
TL Number from the TL Form:
Sample Submitted By Organization: Sequoia Consultants
Sample Organization Contact: (714) 974-6316
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 05/28/2025
Date that the sample was received by the laboratory/organization performing the testing: 05/29/2025
The quantity of what the sample constitutes: 1 per batch
A brief description of the sample: CIP Concrete
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CalPortland

Material Information

The concrete mix design number: 00336362
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 1017685
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: DS2 Headwall Sta. 1293+50
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2025-05-28-127-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 11/17/2025
Date Tested: 06/25/2025
Submitted By Organization: Sequoia Consultants
Organization Address: 361 West Grove Avenue,
Organization City: Orange
Organization State: CA
Organization Zipcode: 92865
Organization Email: sranjan@sequoiacon.com
Organization Phone: 1 (714) 974-6316
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 4160 psi
Maximum load on cylinder 1 119350 lb
Maximum load on cylinder 2 115980 lb
Type of fracture pattern of cylinder 1 1
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 28 days
Age of specimen in hours no data0 hours