Print Report | Back to Sample Detail

Sample Record for 2025-11-07-26

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994443 DEA: 053307C4 EFIS: 0514000028 QA Service Level: 1
DIST-CO-RTE-PM: 05-SLO-41,46-44.5/45.3,54.0/57.8
Work Description: Wye Segment - Route 41/46 Separation
Location Description:
Contractor Name: Atkinson Construction
Contractor Address: 18201 Von Karman - Suite 800, Irvine, CA 92612
Resident Engineer: Brian Harrington Structure Rep.: Dave Lewis

Sample Information

DIME Sample ID: 2025-11-07-26
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - Whitley Gardens Field Laboratory
Sample Organization Contact: 805-540-9933
Type of Sample: Acceptance
Type of Material: Concrete
Sample Taken Date: 11/07/2025
Date that the sample was received by the laboratory/organization performing the testing: 11/07/2025
The quantity of what the sample constitutes: LCB 3 & 7 Day - 12452-LCB-1R Trial Batch
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Manufacturer
Laboratory sample identification: 251107 LCB Trial Batch
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Atkinson Mobile Plant

Material Information

The concrete mix design number: 12452-LCB-1R
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: NA
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Loader
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 4

DIME Test ID: 2025-11-07-26-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 11/12/2025
Date Tested: 11/10/2025
Submitted By Organization: CT D05 - Whitley Gardens Field Laboratory
Organization Address: 102 South Whitley Gardens Drive,
Organization City: Paso Robles
Organization State: CA
Organization Zipcode: 93346
Organization Email: kyle.engen@dot.ca.gov
Organization Phone: (805) 540-9933
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 400 psi
Maximum load on cylinder 1 11459 lb
Maximum load on cylinder 2 11252 lb
Compressive strength of cylinder 1 405.3 psi
Type of fracture pattern of cylinder 1 6
Compressive strength of cylinder 2 398.0 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 3 days
Age of specimen in hours no data0 hours

Test 2 of 4

DIME Test ID: 2025-11-07-26-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 11/19/2025
Date Tested: 11/14/2025
Submitted By Organization: CT D05 - Whitley Gardens Field Laboratory
Organization Address: 102 South Whitley Gardens Drive,
Organization City: Paso Robles
Organization State: CA
Organization Zipcode: 93346
Organization Email: kyle.engen@dot.ca.gov
Organization Phone: (805) 540-9933
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 5.97 in
Average diameter of cylinder 2 5.97 in
Cross sectional area of cylinder 1 27.99 in^2
Cross sectional area of cylinder 2 27.99 in^2
Compressive strength (to nearest 10 psi) 550 psi
Maximum load on cylinder 1 15132 lb
Maximum load on cylinder 2 15749 lb
Compressive strength of cylinder 1 540.6 psi
Type of fracture pattern of cylinder 1 5
Compressive strength of cylinder 2 562.7 psi
Type of fracture pattern of cylinder 2 4
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 7 days
Age of specimen in hours no data0 hours

Test 3 of 4

DIME Test ID: 2025-11-07-26-3
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 11/19/2025
Date Tested: 11/14/2025
Submitted By Organization: CT D05 - Whitley Gardens Field Laboratory
Organization Address: 102 South Whitley Gardens Drive,
Organization City: Paso Robles
Organization State: CA
Organization Zipcode: 93346
Organization Email: kyle.engen@dot.ca.gov
Organization Phone: (805) 540-9933
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 580 psi
Maximum load on cylinder 1 16239 lb
Maximum load on cylinder 2 16377 lb
Compressive strength of cylinder 1 574.4 psi
Type of fracture pattern of cylinder 1 5
Compressive strength of cylinder 2 579.3 psi
Type of fracture pattern of cylinder 2 5
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 7 days
Age of specimen in hours no data0 hours

Test 4 of 4

DIME Test ID: 2025-11-07-26-4
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 11/19/2025
Date Tested: 11/14/2025
Submitted By Organization: CT D05 - Whitley Gardens Field Laboratory
Organization Address: 102 South Whitley Gardens Drive,
Organization City: Paso Robles
Organization State: CA
Organization Zipcode: 93346
Organization Email: kyle.engen@dot.ca.gov
Organization Phone: (805) 540-9933
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 580 psi
Maximum load on cylinder 1 16431 lb
Maximum load on cylinder 2 16475 lb
Compressive strength of cylinder 1 581.2 psi
Type of fracture pattern of cylinder 1 4
Compressive strength of cylinder 2 582.8 psi
Type of fracture pattern of cylinder 2 5
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 7 days
Age of specimen in hours no data