Print Report | Back to Sample Detail

Sample Record for 2025-10-06-72

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000176 DEA: 034H76U4 EFIS: 0323000040 QA Service Level: 1
DIST-CO-RTE-PM: 03-BUT-32-5.0/10.2
Work Description: REHABILITATE PAVEMENT, INSTALL SIGNAL, LIGHTING, DRAINAGE, & ADA RAMPS
Location Description: BUTTE COUNTY IN CHICO FROM MUIR AVENUE TO INTERCHANGE OF STATE ROUTES 99 AND 32
Contractor Name: BALDWIN CONTRACTING COMPANY, INC. DBA KNIFE RIVER CONSTRUCTION
Contractor Address: 1764 SKYWAY, CHICO CA 95928
Resident Engineer: Husam Makhoul Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2025-10-06-72
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Quality Assurance
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 10/06/2025
Date that the sample was received by the laboratory/organization performing the testing: 11/04/2025
The quantity of what the sample constitutes: 1 CAN OF RUBBER
A brief description of the sample: 64-16
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: KNIFE RIVER

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2025-10-06-72-1
Test Method: ASTM D217-21: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 11/18/2025
Date Tested: 11/18/2025
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: CONE PENETRATION
Test Result Compliance: complies
Additional Comments When Verified:
Determination Unworked Penetration
Unworked Penetration 28 0.1 mm

Test 2 of 3

DIME Test ID: 2025-10-06-72-2
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 11/18/2025
Date Tested: 11/18/2025
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: SOFTENING POINT
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 65 C
Softening Point Sample 2 65 C
Bath Liquid freshly boiled distilled water
Minutes Reaction no data

Test 3 of 3

DIME Test ID: 2025-10-06-72-3
Test Method: ASTM D5329-20: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 11/18/2025
Date Tested: 11/18/2025
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: RESILIENCE
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Ball Penetration (P1) 2 mm
Final Dial reading (F1) 64 mm
Ball Penetration (P2) 1 mm
Final Dial reading (F2) 63 mm
Ball Penetration (P3) 3 mm
Final Dial reading (F3) 66 mm
Resilience 1 38 %
Resilience 2 38 %
Resilience 3 37 %
Average Resilience 38 %
Minutes Reaction no data