Print Report | Back to Sample Detail

Sample Record for 2025-10-22-38

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994539 DEA: 021H58U4 EFIS: 0223000059 QA Service Level: 1
DIST-CO-RTE-PM: 02-PLU-70-58.2/R78.4
Work Description: RECONSTRUCT ROADWAY, HMA PAVING, DRAINAGE AND ELECTRICAL WORK.
Location Description: PLUMAS COUNTY AT AND NEAR CROMBERG FROM GILL RANCH ROAD TO 0.2 MILE WEST OF BIG GRIZZLY CREEK BRIDGE
Contractor Name: MERCER-FRASER COMPANY
Contractor Address: PO Box 1006, Eureka, CA 95502
Resident Engineer: Mike Zdenek Structure Rep.: Brandon Thurber

Sample Information

DIME Sample ID: 2025-10-22-38
TL Number from the TL Form:
Sample Submitted By Organization: Atlas - Denver
Sample Organization Contact: 303-975-9959
Type of Sample: Quality Assurance
Type of Material: Asphalt Binder
Sample Taken Date: 10/22/2025
Date that the sample was received by the laboratory/organization performing the testing: 11/03/2025
The quantity of what the sample constitutes: 2 Cans
A brief description of the sample: PG 64-28M
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Western Nevada Materials Spanish Springs

Material Information

Performance Grade: PG 64-28 M
Modified: No
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: Pacific Northwest Oil - Stockton CA
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:

Test Results

Test 1 of 8

DIME Test ID: 2025-10-22-38-1
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 11/20/2025
Date Tested: 11/12/2025
Submitted By Organization: Atlas - Denver
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ian.broddrick@dot.ca.gov
Organization Phone: (916) 741-2680
General Comments for this Test: Original
Test Result Compliance: complies
Additional Comments When Verified:
Phase Original binder
Test Gap 1 mm
Test Frequency 10.0 rad/s
Strain Amplitude 12.06 %
Stress Amplitude 0.333 kPa
Phase Angle (δ) (for the 10 cycles) 62.8 degree
Complex Modulus (G*) (for the 10 measurements) 2.758 kPa
Test Temperature (Specimen 1) 64.0 C
Dynamic Shear, G*/sin(δ) 3.10 kPa

Test 2 of 8

DIME Test ID: 2025-10-22-38-2
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Submitted By Organization: Atlas - Denver
Organization Address: 627 Sheridan Boulevard,
Organization City: Lakewood
Organization State: CO
Organization Zipcode: 80214
Organization Email:
Organization Phone: 303-975-9959
This test has been superseded on 11/20/2025. The corrected test ID is: 2025-10-22-38-8
Reason: corrected

Test 3 of 8

DIME Test ID: 2025-10-22-38-3
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 11/20/2025
Date Tested: 11/14/2025
Submitted By Organization: Atlas - Denver
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ian.broddrick@dot.ca.gov
Organization Phone: (916) 741-2680
General Comments for this Test: RTFO
Test Result Compliance: complies
Additional Comments When Verified:
Phase RTFO residue
Test Gap 1 mm
Test Frequency 10.0 rad/s
Strain Amplitude 10.05 %
Stress Amplitude 0.613 kPa
Phase Angle (δ) (for the 10 cycles) 57.7 degree
Complex Modulus (G*) (for the 10 measurements) 6.098 kPa
Test Temperature (Specimen 1) 64.0 C
Dynamic Shear, G*/sin(δ) 7.21 kPa

Test 4 of 8

DIME Test ID: 2025-10-22-38-4
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 11/20/2025
Date Tested: 11/10/2025
Submitted By Organization: Atlas - Denver
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ian.broddrick@dot.ca.gov
Organization Phone: (916) 741-2680
General Comments for this Test: Mass Change
Test Result Compliance: complies
Additional Comments When Verified:
Is mass change based on one or two containers? Two
Is mass change correction factor needed? Yes
Any material loss from containers during heating process/testing? no data
Mass of container #1 before test (m1i) 209.195 grams
Mass of container #2 before test (m2i) 208.617 grams
Mass of container #1 after test (m1f) 209.108 grams
Mass of container #2 after test (m2f) 208.523 grams
Average mass change -0.229 percent
Mass of empty container #1 174.305 grams
Mass of empty container #2 173.753 grams
Mass correction factor 0.03

Test 5 of 8

DIME Test ID: 2025-10-22-38-5
Test Method: AASHTO T313-22: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Verified Date: 11/20/2025
Date Tested: 11/14/2025
Submitted By Organization: Atlas - Denver
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ian.broddrick@dot.ca.gov
Organization Phone: (916) 741-2680
General Comments for this Test: BBR
Test Result Compliance: complies
Additional Comments When Verified:
Time test started no data HH:MM:SS
Flags issued by software during test no data
Correlation coefficient (R²) no data0
Regression coefficient a no data
Regression coefficient b no data
Regression coefficient c no data
Load at time 0.0 no data0 mN
Deflection at time 0.0 s no data0 µm
Load at time 0.5 s no data0 mN
Deflection at time 0.5 s no data0 µm
Load at 60.0 s no data0 mN
Beam deflection 60.0 s no data0 µm
Measured Stiffness Modulus 60.0 s no data
Estimated Stiffness Modulus 60.0 s 120.983 MPa
Difference between stiffness moduli 60.0 s no data
Estimated m-value 60.0 s 0.376

Test 6 of 8

DIME Test ID: 2025-10-22-38-6
Test Method: AASHTO T316-22: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Verified Date: 11/20/2025
Date Tested: 11/13/2025
Submitted By Organization: Atlas - Denver
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ian.broddrick@dot.ca.gov
Organization Phone: (916) 741-2680
General Comments for this Test: Viscosity @135C
Test Result Compliance: complies
Additional Comments When Verified:
Is viscosity reading in cP/Pa-s? cP
Time of test 00:00 HH:MM
Test Temperature 135 C
Speed 20 rpm
Spindle size .463 in
Torque 44.1 %
Viscosity reading #1 (A) 1102 cP
Viscosity reading #2 (B) 1102 cP
Viscosity reading #3 (C) 1102 cP
Average viscosity 1.102 Pa-s

Test 7 of 8

DIME Test ID: 2025-10-22-38-7
Test Method: AASHTO T301-22: Standard Method of Test for Elastic Recovery Test of Asphalt Materials by Means of a Ductilometer
Verified Date: 11/20/2025
Date Tested: 11/14/2025
Submitted By Organization: Atlas - Denver
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ian.broddrick@dot.ca.gov
Organization Phone: (916) 741-2680
General Comments for this Test: Elastic Recovery
Test Result Compliance: complies
Additional Comments When Verified:
% Elongation Recovery 83 %

Test 8 of 8

DIME Test ID: 2025-10-22-38-8
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 11/20/2025
Date Tested: 11/14/2025
Submitted By Organization: Atlas - Denver
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ian.broddrick@dot.ca.gov
Organization Phone: (916) 741-2680
General Comments for this Test: PAV
The test was superseded from test ID: 2025-10-22-38-2
Test Result Compliance: complies
Additional Comments When Verified:
Phase PAV residue
Test Plate Diameter no data
Test Gap 2 mm
Test Frequency 10.0 rad/s
Strain Amplitude 1.01 %
Stress Amplitude 51.272 kPa
Phase Angle (δ) (for the 10 cycles) 43.9 degree
Complex Modulus (G*) (for the 10 measurements) 5101.485 kPa
Test Temperature (Specimen 1) 22.0 C
(G*) x sin(δ)= no data