Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994583 DEA: 07333604 EFIS: 0716000313
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-2-2.3/14.2
Work Description: COLD PLANE AC, PLACE HMA, REPLACE CURB RAMPS AND TRAFFIC SIGNALS.
Location Description: LOS ANGELES COUNTY IN LOS ANGELES AT VARIOUS LOCATIONS FROM CENTINELA AVENUE TO GLENDALE BOULEVARD UNDERCROSSING
Contractor Name: SULLY-MILLER CONTRACTING COMPANY
Contractor Address: Unknown
Resident Engineer: Denrick Bautista Structure Rep.: Gon Choi
DIME Sample ID: 2025-10-29-14
TL Number from the TL Form:
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Acceptance
Type of Material: Soil
Sample Taken Date: 10/29/2025
Date that the sample was received by the laboratory/organization performing the testing: 10/29/2025
The quantity of what the sample constitutes: 189 CY
A brief description of the sample: aggregate base
From where was the sample collected: Job Site
Laboratory sample identification: 25-3556
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sully Miller
The fabricator's/manufacturer's product name for the sample: aggregate base
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: From various locations at Aggregate Base
Where the material sample would have been placed if not sampled:
DIME Test ID: 2025-10-29-14-1
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Verified Date: 10/30/2025
Date Tested: 10/29/2025
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Is oversize material
|
No
|
|
In-place wet density
|
1.97
|
|
Highest adjust wet density
|
2.13
|
|
Relative compaction
|
92
|
|
% Moisture
|
11.1 %
|
|
Optimum Moisture
|
13.1 %
|
DIME Test ID: 2025-10-29-14-2
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Verified Date: 10/30/2025
Date Tested: 10/29/2025
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Standard Count Density
|
2049 g/cc
|
|
Count or Density 1
|
1.99 g/cc
|
|
Count or Density 2
|
1.95 g/cc
|
|
Count or Density 3
|
1.97 g/cc
|
|
Standard Count Moisture
|
648 g/cc
|
|
Moisture Count 1
|
0.17 g/cc
|
|
Moisture Count 2
|
0.21 g/cc
|
|
Moisture Count 3
|
0.21 g/cc
|
|
Sum of Count or Density
|
5.91 g/cc
|
|
Average of Count or Density
|
1.97 g/cc
|
|
Sum of Moisture Count
|
0.59 g/cc
|
|
Average of Moisture Count
|
0.2 g/cc
|
|
Calculated Percent Relative Compaction
|
92.5 %
|
|