Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000957 DEA: 022K5404 EFIS: 0225000091
QA Service Level: 1
DIST-CO-RTE-PM: 02---
Work Description:
Location Description:
Contractor Name: TULLIS INC
Contractor Address: P O BOX 493416, REDDING CA 96049
Resident Engineer: Daniel Gibbs Structure Rep.: Unknown
DIME Sample ID: 2025-10-11-12
TL Number from the TL Form: 875614
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 10/11/2025
Date that the sample was received by the laboratory/organization performing the testing: 10/17/2025
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: 2 boxes of Lime Treated 3/4-inch Type A HMA (eq. PG 64-28M) with 25% RAP and virgin PG 58-34M from Valero (Benicia, CA)
From where was the sample collected: Manufacturer
Laboratory sample identification: D80095
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Tullis Inc. - Northstate Asphalt (Redding CA)
HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number:
Binder content (%): 4.7
Virgin binder PG: PG 58-34M
Design binder PG: PG 64-28M
Binder Supplier: Valero (Benicia, CA)
RAP content (%): 25
WMA Additives: No
Antistrip type: 1.0% Lime
DIME Test ID: 2025-10-11-12-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 10/23/2025
Date Tested: 10/22/2025
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pb=4.77,
TV=4.70
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3155.8 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
4862.4 g
|
|
Mass of HMA Sample prior to ignition
|
1706.6 g
|
|
Corrected Asphalt Binder Content
|
4.77 %
|
|
Mass Loss
|
97.9 g
|
|
Mass of aggregate remaining after ignition
|
1608.7 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.79 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.18 %
|
|
Test Temperature
|
538 C
|