Print Report | Back to Sample Detail

Sample Record for 2025-08-14-150

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214649 DEA: 07316004 EFIS: 0715000194 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-14-60.70
Work Description: REHABILITATION FOR THE ON/OFF RAMPS AND ADJACENT SHOULDERS. UPGRADING METAL BEAM GUARDRAILS, AC DIKES, SIGN PANELS, CURB RAMPS, TRAFFIC LOOPS DETECTORS, AND SOME OTHER HIGHWAY APPURTENANCES.
Location Description: ROUTE 14 FROM PALMDALE BLVD TO KERN COUNTRY LINE.
Contractor Name: Guy F. Atkinson Construction LLC
Contractor Address: 18201 Von Karman Ave, Suite 800, Irvine, CA 92612
Resident Engineer: James Shih Structure Rep.: Hossein Sabbagh

Sample Information

DIME Sample ID: 2025-08-14-150
TL Number from the TL Form:
Sample Submitted By Organization: Alta Vista Solutions - Whittier
Sample Organization Contact: (510) 542-9827
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 08/14/2025
Date that the sample was received by the laboratory/organization performing the testing: 08/14/2025
The quantity of what the sample constitutes: 1030 CY
A brief description of the sample: JPCP 6x12 Cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 25-2731
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: N/A

Material Information

The concrete mix design number: SCI-12622-1
The truck number from where the sample was collected: Truck or Ticket 103
The batch plant ticket number from where the sample was collected: Load 103
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Jobsite
Where the material sample would have been placed if not sampled: Jobsite
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2025-08-14-150-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 10/21/2025
Date Tested: 09/25/2025
Submitted By Organization: Alta Vista Solutions - Whittier
Organization Address: 12409 Slauson Avenue, Suite I,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90606
Organization Email: nicholas.hoffmann@oneatlas.com
Organization Phone: (510) 542-9827
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 5.97 in
Average diameter of cylinder 2 5.97 in
Average diameter of cylinder 3 5.97 in
Cross sectional area of cylinder 1 27.99 in^2
Cross sectional area of cylinder 2 27.99 in^2
Cross sectional area of cylinder 3 27.99 in^2
Compressive strength (to nearest 10 psi) 4680 psi
Maximum load on cylinder 1 129393 lb
Maximum load on cylinder 2 131424 lb
Maximum load on cylinder 3 132525 lb
Compressive strength of cylinder 1 4622.8 psi
Type of fracture pattern of cylinder 1 5
Compressive strength of cylinder 2 4695.4 psi
Compressive strength of cylinder 3 4734.7 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 42 days
Age of specimen in hours no data0 hours