Print Report | Back to Sample Detail

Sample Record for 2025-10-16-34

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000365 DEA: 033H9014 EFIS: 0323000075 QA Service Level: 1
DIST-CO-RTE-PM: 03-SOL,YOL-50,80,113-Var
Work Description: HMA, RHMA, SIGN STRUCTURE, CAMERA SYSTEMS, & FO CABLE SYSTEMS.
Location Description: SOLANO AND YOLO COUNTIES AT VARIOUS LOCATIONS
Contractor Name: DESILVA GATES CONSTRUCTION, LLC
Contractor Address: 3855 North Freeway Boulevard, Suite 100, Sacramento, CA 95834
Resident Engineer: Joseph Wild Structure Rep.: Michael Charak

Sample Information

DIME Sample ID: 2025-10-16-34
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Quality Assurance
Type of Material: Asphalt Binder
Sample Taken Date: 10/16/2025
Date that the sample was received by the laboratory/organization performing the testing: 10/21/2025
The quantity of what the sample constitutes: 1 CAN OF BINDER
A brief description of the sample: 58-22
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Valero Benecia

Material Information

Performance Grade: PG 58-22
Modified:
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: Valero Marketing & Supply - Benicia CA
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:

Test Results

Test 1 of 1

DIME Test ID: 2025-10-16-34-1
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 10/27/2025
Date Tested: 10/27/2025
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: OG
Test Result Compliance: complies
Additional Comments When Verified:
Phase Original binder
Test Gap 1 mm
Test Frequency 10.0 rad/s
Strain Amplitude 12.06 %
Stress Amplitude 0.167 kPa
Phase Angle (δ) (for the 10 cycles) 86.4 degree
Complex Modulus (G*) (for the 10 measurements) 1.382 kPa
Test Temperature (Specimen 1) 58.0 C
Dynamic Shear, G*/sin(δ) 1.38 kPa