Print Report | Back to Sample Detail

Sample Record for 2025-10-06-57

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994901 DEA: 112T3434 EFIS: 1120000081 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-805-5.1/8.3
Work Description: SOUNDWALLS, WIDEN FREEWAY, STRUCTURES, LANDSCAPE AND ELECTRICAL.
Location Description: SAN DIEGO COUNTY IN CHULA VISTA FROM PALOMAR STREET OVERCROSSING TO 0.5 MILE NORTH OF BONITA ROAD UNDERCROSSING
Contractor Name: WALSH CONSTRUCTION COMPANY II, LLC
Contractor Address: 1260 Corona Pointe Court #201
Resident Engineer: Tan Cao Structure Rep.: Daniela Gomez

Sample Information

DIME Sample ID: 2025-10-06-57
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Per Request
Type of Material: Aggregate
Sample Taken Date: 10/06/2025
Date that the sample was received by the laboratory/organization performing the testing: 10/07/2025
The quantity of what the sample constitutes: 3 bags
A brief description of the sample: PSU
From where was the sample collected: Source
Laboratory sample identification: 2025-10-06-57-PSU
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Otay

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-37-0035
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number: 220200 Otay Val

Test Results

Test 1 of 12

DIME Test ID: 2025-10-06-57-11
Test Method: CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)
Verified Date: 10/17/2025
Date Tested: 10/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
Plastic limit (PL) 1 %

Test 2 of 12

DIME Test ID: 2025-10-06-57-9
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 10/17/2025
Date Tested: 10/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7475.6 grams
Mass of oven-dry sample in air for Sample 1 1550.2 grams
Mass of container filled with the sample and water for Sample 1 8400.9 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.481
Theoretical maximum density at 25°C (77°F) 154.4 lb/ft^3

Test 3 of 12

DIME Test ID: 2025-10-06-57-4
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 10/17/2025
Date Tested: 10/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
Sand Equivalent 77

Test 4 of 12

DIME Test ID: 2025-10-06-57-12
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 10/17/2025
Date Tested: 10/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies per the Mix Design 35-11 Grading Analysis
Test Result Compliance: complies
Additional Comments When Verified:
Is an aggregate correction factor used? No
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 95 %
Cumulative percent passing the 1/2 in. sieve 81 %
Cumulative percent passing the 3/8 in. sieve 73 %
Cumulative percent passing the #4 sieve 50 %
Cumulative percent passing the #8 sieve 40 %
Cumulative percent passing the #16 sieve 27 %
Cumulative percent passing the #30 sieve 21 %
Cumulative percent passing the #50 sieve 14 %
Cumulative percent passing the #100 sieve 6 %
Cumulative percent passing the #200 sieve 3.5 %

Test 5 of 12

DIME Test ID: 2025-10-06-57-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 10/17/2025
Date Tested: 10/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What type of gradation is being tested? Combined Gradation
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 96 %
Cumulative percent passing the 1/2 in. sieve 70 %
Cumulative percent passing the 3/8 in. sieve 58 %
Cumulative percent passing the #4 sieve 40 %
Cumulative percent passing the #8 sieve 32 %
Cumulative percent passing the #16 sieve 21 %
Cumulative percent passing the #30 sieve 15 %
Cumulative percent passing the #50 sieve 9 %
Cumulative percent passing the #100 sieve 4 %
Cumulative percent passing the #200 sieve 2.7 %

Test 6 of 12

DIME Test ID: 2025-10-06-57-3
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Verified Date: 10/17/2025
Date Tested: 10/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
Method B
Determination By Number
Dimensional ratio used 5:1
Weighted percentage of particles (by number) that were flat and elongated 0 %
Weighted percentage of particles (by number) that were not flat and elongated 0 %

Test 7 of 12

DIME Test ID: 2025-10-06-57-2
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 10/17/2025
Date Tested: 10/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
Method 1 - Combined Fracture Determination
Aggregate Size and Fracture Type Coarse 2 Faced and Fine 1 Faced
Percentage of questionable, coarse, 2 faced particles tested no data0 %
Percentage of questionable, fine, 1 faced particles tested no data0 %
Percentage of fractured, coarse, 2 faced particles tested 100 %
Percentage of fractured, fine, 1 faced particles tested 100 %

Test 8 of 12

DIME Test ID: 2025-10-06-57-5
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Verified Date: 10/17/2025
Date Tested: 10/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
Bulk specific gravity 2.583
Bulk specific gravity (SSD Basis) 2.648
Apparent specific gravity 2.763
Absorption 2.5 %

Test 9 of 12

DIME Test ID: 2025-10-06-57-6
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Verified Date: 10/17/2025
Date Tested: 10/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
Basis for relative density testing Bulk
Specific Gravity 2.673
Absorption 1.1 %

Test 10 of 12

DIME Test ID: 2025-10-06-57-7
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Verified Date: 10/17/2025
Date Tested: 10/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
Grading designation B
Mass of sample on No.12 sieve (after 500 revolutions) 4358 grams
Percent loss after 100 revolutions 3 %
Percent loss after 500 revolutions 13 %

Test 11 of 12

DIME Test ID: 2025-10-06-57-8
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Verified Date: 10/17/2025
Date Tested: 10/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
What test method is performed? Method A
Bulk dry specific gravity 2.583
Average uncompacted voids 45 %

Test 12 of 12

DIME Test ID: 2025-10-06-57-13
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 10/17/2025
Date Tested: 10/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: RAP
Test Result Compliance:
Additional Comments When Verified:
Is an aggregate correction factor used? Yes
Aggregate correction factor for the 2 in. sieve (% passing) no data0 %
Aggregate correction factor for the 1 1/2 in. sieve (% passing) no data0 %
Aggregate correction factor for the 1 in. sieve (% passing) no data0 %
Aggregate correction factor for the 3/4 in. sieve (% passing) no data0 %
Aggregate correction factor for the 1/2 in. sieve (% passing) no data0 %
Aggregate correction factor for the 3/8 in. sieve (% passing) -0.4 %
Aggregate correction factor for the #4 sieve (% passing) -2.4 %
Aggregate correction factor for the #8 sieve (% passing) -1 %
Aggregate correction factor for the #16 sieve (% passing) -1.7 %
Aggregate correction factor for the #30 sieve (% passing) -2.3 %
Aggregate correction factor for the #50 sieve (% passing) -2 %
Aggregate correction factor for the #100 sieve (% passing) -1.7 %
Aggregate correction factor for the #200 sieve (% passing) -1.6 %
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 100 %
Cumulative percent passing the 3/8 in. sieve 99 %
Cumulative percent passing the #4 sieve 81 %
Cumulative percent passing the #8 sieve 67 %
Cumulative percent passing the #16 sieve 50 %
Cumulative percent passing the #30 sieve 36 %
Cumulative percent passing the #50 sieve 22 %
Cumulative percent passing the #100 sieve 14 %
Cumulative percent passing the #200 sieve 9.1 %