Project ID: 993331 DEA: 023H6904 EFIS: 0218000010
QA Service Level: 1
DIST-CO-RTE-PM: 02-PLU-89-30/R42.1
Work Description: ALMANOR WEST REHAB - ROADWAY REHABILITATION
Location Description: IN PLUMAS COUNTY NEAR CANYON DAM FROM LAKE ALMANOR SPILLWAY TO ROUTE 36.
Contractor Name: DIG IT CONSTRUCTION, INC.
Contractor Address: Unknown
Resident Engineer: Sergio Mendoza Structure Rep.: Unknown
DIME Sample ID: 2025-09-19-56
TL Number from the TL Form: 848634
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 09/19/2025
Date that the sample was received by the laboratory/organization performing the testing: 09/25/2025
The quantity of what the sample constitutes: 20,000 Tons
A brief description of the sample: 12 Boxes of Lime Treated 3/4-inch HMA-A, w/ 24% RAP, PG 58-34 Albina (K-Falls)
From where was the sample collected: Manufacturer
Laboratory sample identification: D80061
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Dig It Construction – Sierra Cascade Aggregate and Asphalt Products (Chester, CA)
HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number:
Binder content (%): 5.9
Virgin binder PG:
Design binder PG: PG 64-28
Binder Supplier: Albina (Klamath Falls, OR)
RAP content (%): 24
WMA Additives: No
Antistrip type: 1.0% Lime
DIME Test ID: 2025-09-19-56-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 10/15/2025
Date Tested: 09/25/2025
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmm=2.408
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Number of tests
|
1
|
|
What is the unit of measurement for theoretical density?
|
SI Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water
|
7331 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
2636.9 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8873 grams
|
|
Temperature of Water
|
76 °F
|
|
Specific Gravity for Sample 1
|
2.408
|
|
Theoretical maximum density at 25°C (77°F)
|
2401 kg/m^3
|
DIME Test ID: 2025-09-19-56-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 10/15/2025
Date Tested: 10/06/2025
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pb=5.39%, TV=5.85%
Test Result Compliance: does not comply
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3030.2 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5216.6 g
|
|
Mass of HMA Sample prior to ignition
|
2186.4 g
|
|
Corrected Asphalt Binder Content
|
5.39 %
|
|
Mass Loss
|
133.5 g
|
|
Mass of aggregate remaining after ignition
|
2052.9 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.58 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.14 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2025-09-19-56-3
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 10/15/2025
Date Tested: 10/10/2025
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: S1=64 psi, S2=54 psi, TSR=85%
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
SI Units
|
|
Average Dry Tensile Strength
|
64 psi
|
|
Average Wet Tensile Strength
|
54 psi
|
|
Tensile Strength Ratio
|
0.84
|
DIME Test ID: 2025-09-19-56-4
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 10/15/2025
Date Tested: 10/01/2025
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmb=2.263
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.245
|
|
Bulk Specific Gravity 2
|
2.274
|
|
Bulk Specific Gravity 3
|
2.27
|
|
Average Bulk Specific Gravity
|
2.263
|
DIME Test ID: 2025-09-19-56-5
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 10/15/2025
Date Tested: 10/02/2025
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pa=6.0%
Test Result Compliance: complies
Additional Comments When Verified:
|
Percent Air Voids
|
6.8 %
|
|
Percent Air Voids 2
|
5.6 %
|
|
Percent Air Voids 3
|
5.7 %
|
|
Average Percent Air Voids
|
6 %
|