Print Report | Back to Sample Detail

Sample Record for 2025-10-09-49

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000665 DEA: 081K4004 EFIS: 0819000031 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-15-3.5/6.8
Work Description: HMA (TYPE A), RDWY EXC, STR CONC RET WALL, RUBBERIZED HMA (OGFC).
Location Description: TEMECULA FROM 0.1 MI NORTH OF TEMECULA PARKWAY TO 0.2 MI NORTH OF WINCHESTER ROAD
Contractor Name: BEADOR CONSTRUCTION COMPANY, INC.
Contractor Address: 2900 Bristol Street, Suite D204, Costa Mesa, CA 92626
Resident Engineer: Denise Sostrom Structure Rep.: Gizachew Abayneh

Sample Information

DIME Sample ID: 2025-10-09-49
TL Number from the TL Form: 1079-109CW
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 10/09/2025
Date that the sample was received by the laboratory/organization performing the testing: 10/14/2025
The quantity of what the sample constitutes: 9
A brief description of the sample: 4x8 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 1079-109CW
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: *

Material Information

The concrete mix design number: Not Provided
The truck number from where the sample was collected: 10070453
The batch plant ticket number from where the sample was collected: 31771498
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: SB15 Empire Creek Bent 2 Column Wrap
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 2

DIME Test ID: 2025-10-09-49-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C1231 - Unbonded Elastomeric Pad Cap
Cured in accordance with ASTM C511
Verified Date: 10/24/2025
Date Tested: 10/16/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Cross sectional area of cylinder 1 12.63 in^2
Cross sectional area of cylinder 2 12.63 in^2
Cross sectional area of cylinder 3 12.63 in^2
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Compressive strength (to nearest 10 psi) 3940 psi
Average diameter of cylinder 1 4.01 in
Average diameter of cylinder 2 4.01 in
Compressive strength of cylinder 1 3958.0 psi
Compressive strength of cylinder 2 3947.0 psi
Average diameter of cylinder 3 4.01 in
Compressive strength of cylinder 3 3901 psi
Maximum load on cylinder 1 49990 lb
Maximum load on cylinder 2 49850 lb
Maximum load on cylinder 3 49270 lb
Type of fracture pattern of cylinder 1 1
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 7 days

Test 2 of 2

DIME Test ID: 2025-10-09-49-2
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C1231 - Unbonded Elastomeric Pad Cap
Cured in accordance with ASTM C511
Verified Date: 10/24/2025
Date Tested: 10/23/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Cross sectional area of cylinder 1 12.63 in^2
Cross sectional area of cylinder 2 12.63 in^2
Cross sectional area of cylinder 3 12.69 in^2
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Compressive strength (to nearest 10 psi) 5080 psi
Average diameter of cylinder 1 4.01 in
Average diameter of cylinder 2 4.01 in
Compressive strength of cylinder 1 5124.3 psi
Compressive strength of cylinder 2 5033.3 psi
Average diameter of cylinder 3 4.02 in
Compressive strength of cylinder 3 5086.7 psi
Maximum load on cylinder 1 64720 lb
Maximum load on cylinder 2 63570 lb
Maximum load on cylinder 3 64550 lb
Type of fracture pattern of cylinder 1 3
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 14 days

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2025-10-09-49-3ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens10/14/202511/06/2025Matthew ClaytonCT D08 - Fontana Southern Regional Laboratory