Print Report | Back to Sample Detail

Sample Record for 2025-09-30-31

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000501 DEA: 081J6104 EFIS: 0818000102 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-215-40.5/42.7
Work Description: INDIVIDUAL SLAB REPLACEMENT (RSC), RHMA, AND REPLACE BASE.
Location Description: RIVERSIDE COUNTY IN RIVERSIDE FROM 0.8 MILE SOUTH OF ROUTE 60/91 SEPARATION TO 0.4 MILE SOUTH OF MARTIN LUTHER KING BOULEVARD UNDERCROSSING
Contractor Name: FBD VANGUARD CONSTRUCTION, INC.
Contractor Address: 550 Greenville Rd., Livermore, CA
Resident Engineer: Mahfual Alam Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2025-09-30-31
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 09/30/2025
Date that the sample was received by the laboratory/organization performing the testing: 10/01/2025
The quantity of what the sample constitutes: 3
A brief description of the sample: 6X12
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: VULCAN

Material Information

The concrete mix design number: *
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 6702
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: 215 NB STA61+00
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2025-09-30-31-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 10/17/2025
Date Tested: 10/07/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Apparent mass of submerged cylinder 1 no data0 lb
Average diameter of cylinder 1 6.04 in
Average diameter of cylinder 2 6.03 in
Average diameter of cylinder 3 6.03 in
Cross sectional area of cylinder 1 28.65 in^2
Cross sectional area of cylinder 2 28.56 in^2
Cross sectional area of cylinder 3 28.56 in^2
Compressive strength (to nearest 10 psi) 8110 psi
Maximum load on cylinder 1 232445 lb
Maximum load on cylinder 2 236605 lb
Maximum load on cylinder 3 226550 lb
Compressive strength of cylinder 1 8110.0 psi
Type of fracture pattern of cylinder 1 1
Compressive strength of cylinder 2 8280.0 psi
Compressive strength of cylinder 3 7930 psi
Type of fracture pattern of cylinder 2 1
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 7 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data