Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000164 DEA: 081N7804 EFIS: 0823000048
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-40-R129.8/R135.9
Work Description: RUBBERIZED HMA, COLD PLANE AC PVMT AND REPLACE AC SURFACING.
Location Description: SAN BERNARDINO COUNTY FROM 2.9 MILES WEST TO 3.2 MILES EAST OF ROUTE 95
Contractor Name: SULLY-MILLER CONTRACTING COMPANY
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2025-09-23-53
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 09/23/2025
Date that the sample was received by the laboratory/organization performing the testing: 09/25/2025
The quantity of what the sample constitutes: 1can
A brief description of the sample: Asphalt Rubber Binder
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Blue Diamond-Victorville
Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:
DIME Test ID: 2025-09-23-53-1
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 10/08/2025
Date Tested: 09/26/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
ASTM Thermometer used?
|
C
|
|
Softening Point Sample 1
|
61 C
|
|
Softening Point Sample 2
|
61 C
|
|
Bath Liquid
|
freshly boiled distilled water
|
|
Minutes Reaction
|
no data
|
DIME Test ID: 2025-09-23-53-2
Test Method: ASTM D217-21: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 10/08/2025
Date Tested: 09/27/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Determination
|
Unworked Penetration
|
|
Unworked Penetration
|
37 0.1 mm
|
DIME Test ID: 2025-09-23-53-3
Test Method: ASTM D5329-20: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 10/08/2025
Date Tested: 09/27/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Temperature
|
25 C
|
|
Ball Penetration (P1)
|
8 mm
|
|
Final Dial reading (F1)
|
76 mm
|
|
Ball Penetration (P2)
|
2 mm
|
|
Final Dial reading (F2)
|
72 mm
|
|
Ball Penetration (P3)
|
3 mm
|
|
Final Dial reading (F3)
|
73 mm
|
|
Resilience 1
|
32 %
|
|
Resilience 2
|
30 %
|
|
Resilience 3
|
30 %
|
|
Average Resilience
|
31 %
|
|
Minutes Reaction
|
no data
|