Print Report | Back to Sample Detail

Sample Record for 2025-09-29-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000611 DEA: 120R32U4 EFIS: 1222000054 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-55-0.2/R17.8
Work Description: COLD PLANE, PLACE RHMA, REPLACE CB, SIGNS AND MODIFY LIGHTING SYSTEM.
Location Description: ORANGE COUNTY FROM 0.1 MILE SOUTH OF ROUTE 55/1 SEPARATION IN NEWPORT BEACH TO ROUTE 55/91 SEPARATION IN ANAHEIM
Contractor Name: R.J. NOBLE COMPANY
Contractor Address: 15505 East Lincoln Avenue, Orange, CA 92865
Resident Engineer: Tyrone Taylor Structure Rep.: Matthew Chang

Sample Information

DIME Sample ID: 2025-09-29-2
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 09/29/2025
Date that the sample was received by the laboratory/organization performing the testing: 10/13/2025
The quantity of what the sample constitutes: 1 double ended rod, 4 heavy hex nuts, 2 hardened washers
A brief description of the sample: (1x) 1"x13" Double end stud F1554 G55 S1, W/ 1" ASTM A563 (4x) 1" Heavy 2H/DH hex nuts, (2x) F436 washers, all HDG
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Halo Structural Products

Material Information

Rocap Number(s):
Heat Number(s): 245879, 8000029706, 32312470
Nut Mfg. Lot Number(s): W000184115
Washer Mfg. Lot Number(s): E6242
Bolt Specification: ASTM F1554 (G55)
Bolt Length(s): 13
Nut Specification: ASTM A563
Washer Specification: ASTM F436
Finish: HDG
Diameter/Size: 1
Bolt Mfg. Lot Number:
Rocap Test Requirement(s):
Lubricant Requirements(s):
Washer Inner Diameter(s):

Test Results

Test 1 of 15

DIME Test ID: 2025-09-29-2-1
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 10/24/2025
Date Tested: 10/13/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 245879
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW
Size 1 in
Bolt Length 13 in
Pitch Diameter 0.918 in
Pitch Diameter 2nd 0.918 in

Test 2 of 15

DIME Test ID: 2025-09-29-2-2
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 10/24/2025
Date Tested: 10/13/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) 245879
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW
Size 1 in
Bolt Length 13 in
Pitch Diameter 0.9285 in
Pitch Diameter 2nd 0.9285 in

Test 3 of 15

DIME Test ID: 2025-09-29-2-3
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/24/2025
Date Tested: 10/21/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 245879
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size no data in
Bolt Length no data in
Measurement Average 7.4 mils

Test 4 of 15

DIME Test ID: 2025-09-29-2-4
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/24/2025
Date Tested: 10/21/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) 245879
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size no data in
Bolt Length no data in
Measurement Average 4.6 mils

Test 5 of 15

DIME Test ID: 2025-09-29-2-5
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/24/2025
Date Tested: 10/21/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number W000184115
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 1 in
Bolt Length no data in
Measurement Average 2.6 mils

Test 6 of 15

DIME Test ID: 2025-09-29-2-6
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/24/2025
Date Tested: 10/21/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number W000184115
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 1 in
Bolt Length no data in
Measurement Average 3.2 mils

Test 7 of 15

DIME Test ID: 2025-09-29-2-7
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/24/2025
Date Tested: 10/21/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number W000184115
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 1 in
Bolt Length no data in
Measurement Average 3.5 mils

Test 8 of 15

DIME Test ID: 2025-09-29-2-8
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/24/2025
Date Tested: 10/21/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number E6242
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 1 in
Bolt Length no data in
Measurement Average 2.8 mils

Test 9 of 15

DIME Test ID: 2025-09-29-2-9
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/24/2025
Date Tested: 10/21/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number E6242
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 1 in
Bolt Length no data in
Measurement Average 2.7 mils

Test 10 of 15

DIME Test ID: 2025-09-29-2-10
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/24/2025
Date Tested: 10/21/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number E6242
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 1 in
Bolt Length no data in
Measurement Average 3.1 mils

Test 11 of 15

DIME Test ID: 2025-09-29-2-11
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 10/24/2025
Date Tested: 10/21/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number E6242
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 1 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 28
Spacing Ok

Test 12 of 15

DIME Test ID: 2025-09-29-2-12
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 10/24/2025
Date Tested: 10/21/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number E6242
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 1 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 28
Spacing Ok

Test 13 of 15

DIME Test ID: 2025-09-29-2-13
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 10/24/2025
Date Tested: 10/21/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number E6242
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 1 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 22
Spacing Ok

Test 14 of 15

DIME Test ID: 2025-09-29-2-15
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 10/24/2025
Date Tested: 10/21/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples 2
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
1A24587915465000yield 42810Kent Allen
1B24587915197000yield 41720Kent Allen
UTM NA
Temperature 0 f

Test 15 of 15

DIME Test ID: 2025-09-29-2-16
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 10/24/2025
Date Tested: 10/21/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples 3
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
1AW00018411519090000NAKent Allen
1BW00018411519090000NAKent Allen
1CW00018411519090000NAKent Allen
UTM NA
Temperature 0 f