Project Information

Project ID: 1000211 DEA: 112N0204 EFIS: 1117000168 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-76-R17.2/24.1
Work Description: COLD PLANE AND OVERLAY WITH RHMA GAP GRADED.
Location Description: SAN DIEGO COUNTY NEAR PALA FROM ROUTE 76/15 SEPARATION TO PALA MISSION ROAD
Contractor Name: GRIFFITH COMPANY
Contractor Address: 13400 Sabre Spring Parkway Ste 200, San Diego, CA 92128
Resident Engineer: Fahad Masud Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2025-08-27-84
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Per Request
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/27/2025
Date that the sample was received by the laboratory/organization performing the testing: 09/04/2025
The quantity of what the sample constitutes: 4 Boxes
A brief description of the sample: Plant Sample
From where was the sample collected: Supplier
Laboratory sample identification: 25-08-27-84-A
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Corona

Material Information

HMA Type: RHMA-G
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number: 326122 CORD SJR
Binder content (%): 7.5
Virgin binder PG: PG 64-16
Design binder PG: PG 64-16
Binder Supplier: SJR
RAP content (%): 0
WMA Additives: Yes
Antistrip type:

Test Results

Test 1 of 2

DIME Test ID: 2025-08-27-84-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 09/30/2025
Date Tested: 09/29/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Target - 7.5% Does Not Comply
Test Result Compliance: does not comply
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 4073.2 g
Mass of the specimen and specimen basket assembly prior to ignition 5610.5 g
Mass of HMA Sample prior to ignition 1537.3 g
Corrected Asphalt Binder Content 6.69 %
Mass Loss 106.5 g
Mass of aggregate remaining after ignition 1430.8 g
Correction Factor (Percent by mass of HMA Specimen) 0.24 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C

Test 2 of 2

DIME Test ID: 2025-08-27-84-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 09/30/2025
Date Tested: 09/29/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Target - 2.436 Complies
Test Result Compliance: complies
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7475.6 grams
Mass of oven-dry sample in air for Sample 1 1511.1 grams
Mass of container filled with the sample and water for Sample 1 8364.3 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.428
Theoretical maximum density at 25°C (77°F) 151.1 lb/ft^3