Print Report | Back to Sample Detail

Sample Record for 2025-09-25-8

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000176 DEA: 034H76U4 EFIS: 0323000040 QA Service Level: 1
DIST-CO-RTE-PM: 03-BUT-32-5.0/10.2
Work Description: REHABILITATE PAVEMENT, INSTALL SIGNAL, LIGHTING, DRAINAGE, & ADA RAMPS
Location Description: BUTTE COUNTY IN CHICO FROM MUIR AVENUE TO INTERCHANGE OF STATE ROUTES 99 AND 32
Contractor Name: BALDWIN CONTRACTING COMPANY, INC. DBA KNIFE RIVER CONSTRUCTION
Contractor Address: 1764 SKYWAY, CHICO CA 95928
Resident Engineer: Husam Makhoul Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2025-09-25-8
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 09/25/2025
Date that the sample was received by the laboratory/organization performing the testing: 09/29/2025
The quantity of what the sample constitutes: 96 Assy
A brief description of the sample: ASTM F1554 GR 55 Anchor Bolt Assy
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Halo Structural Products

Material Information

Rocap Number(s):
Heat Number(s): Rod 20979580 Nut 245119 Washer 32507650
Nut Mfg. Lot Number(s): W54001
Washer Mfg. Lot Number(s): 0425-639
Bolt Specification: ASTM F155 GR55
Bolt Length(s): 42"
Nut Specification: ASTM A194 2H/DH
Washer Specification: ASTM F436
Finish: HDG
Diameter/Size: 2.25
Bolt Mfg. Lot Number:
Rocap Test Requirement(s):
Lubricant Requirements(s):
Washer Inner Diameter(s): 1

Test Results

Test 1 of 13

DIME Test ID: 2025-09-25-8-1
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 10/08/2025
Date Tested: 10/01/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 20979580
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW
Size 2.25 in
Bolt Length 42 in
Pitch Diameter 2.1295 in
Pitch Diameter 2nd 2.1295 in

Test 2 of 13

DIME Test ID: 2025-09-25-8-2
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 10/08/2025
Date Tested: 10/01/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) 20979580
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW
Size 2.25 in
Bolt Length 42 in
Pitch Diameter 2.127 in
Pitch Diameter 2nd 2.127 in

Test 3 of 13

DIME Test ID: 2025-09-25-8-3
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/08/2025
Date Tested: 10/07/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 20979580
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 2.25 in
Bolt Length 42 in
Measurement Average 6.3 mils

Test 4 of 13

DIME Test ID: 2025-09-25-8-4
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/08/2025
Date Tested: 10/07/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) 20979580
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 2.25 in
Bolt Length 42 in
Measurement Average 5.5 mils

Test 5 of 13

DIME Test ID: 2025-09-25-8-5
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/08/2025
Date Tested: 10/07/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number W54001
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 2.25 in
Bolt Length no data in
Measurement Average 4.5 mils

Test 6 of 13

DIME Test ID: 2025-09-25-8-6
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/08/2025
Date Tested: 10/07/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number W54001
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 2.25 in
Bolt Length no data in
Measurement Average 3.2 mils

Test 7 of 13

DIME Test ID: 2025-09-25-8-7
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/08/2025
Date Tested: 10/07/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 0425-639
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 2.25 in
Bolt Length no data in
Measurement Average 10.1 mils

Test 8 of 13

DIME Test ID: 2025-09-25-8-8
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/08/2025
Date Tested: 10/07/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 0425-639
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 2.25 in
Bolt Length no data in
Measurement Average 3 mils

Test 9 of 13

DIME Test ID: 2025-09-25-8-9
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 10/08/2025
Date Tested: 10/07/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number W54001
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 2.25 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 31.3
Spacing Ok

Test 10 of 13

DIME Test ID: 2025-09-25-8-10
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 10/08/2025
Date Tested: 10/07/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number W54001
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 2.25 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 31.3
Spacing Ok

Test 11 of 13

DIME Test ID: 2025-09-25-8-11
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 10/08/2025
Date Tested: 10/07/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 0425-639
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 2.25 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 37.9
Spacing Ok

Test 12 of 13

DIME Test ID: 2025-09-25-8-12
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 10/08/2025
Date Tested: 10/07/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 0425-639
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 2.25 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 40.2
Spacing Ok

Test 13 of 13

DIME Test ID: 2025-09-25-8-13
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 10/08/2025
Date Tested: 10/07/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 2
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
1A209795802.253.2561714861940000Atlas
1B209795802.253.2561769854490000Atlas
UTM NA
Temperature 0 f