Print Report | Back to Sample Detail

Sample Record for 2025-09-14-6

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001223 DEA: 070W2104 EFIS: 0721000087 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-2-R18.7
Work Description: PLACE CLASS 3 AGGREGATE BASE AND HOT MIX ASPHALT.
Location Description: LOS ANGELES COUNTY IN LOS ANGELES AT LOS ANGELES REGIONAL TRANSPORTATION MANAGEMENT CENTER AT 2901 AT WEST BROADWAY
Contractor Name: SPLICE CONSTRUCTION CO, INC.
Contractor Address: 288441 Rancho De Linda, Laguna Niguel, CA 92677
Resident Engineer: Abdulraouf Daaboul Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2025-09-14-6
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 09/14/2025
Date that the sample was received by the laboratory/organization performing the testing: 09/19/2025
The quantity of what the sample constitutes: 6 bags comb agg, 2 bags RAP
A brief description of the sample: PSUE 1/2" WMA-A-SP R25 0.25% EVO
From where was the sample collected: Manufacturer
Laboratory sample identification: 0594A-25
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Fish Canyon Irwindale/ Vulcan Sun Valley/ Ingevity/ VLO

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-19-0035, 91-19-0016
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: belt cut vulcan sun valley
Where the material sample would have been placed if not sampled: Asphalt Paving
Primary Aggregate Nominal Size: 1/2 inch
The concrete mix design number: 320200W SVA VLO
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2025-09-14-6-1AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)09/19/2025Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory
2025-09-14-6-2AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)09/19/2025Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory
2025-09-14-6-3AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)09/19/2025Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory
2025-09-14-6-4AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)09/19/2025Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory
2025-09-14-6-5AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)09/19/2025Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory
2025-09-14-6-6AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)09/19/2025Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory
2025-09-14-6-7AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)09/19/2025Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory
2025-09-14-6-8ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)09/19/2025Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory
2025-09-14-6-9CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates09/19/2025Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory
2025-09-14-6-10CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates09/19/2025Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory