Print Report | Back to Sample Detail

Sample Record for 2025-09-03-56

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000392 DEA: 07349904 EFIS: 0718000167 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-710-6.0/14.1
Work Description: CONSTRUCT MVPS, MGS, ROCK BLANKETS,AND PAVE BEYOND THE GORE.
Location Description: LOS ANGELES COUNTY IN LONG BEACH AND COMPTOM FROM SHORELINE DRIVE TO 0.2 MILE NORTH OF ALONDRA BOULEVARD OVERCROSSING
Contractor Name: WESTCOAST PUBLIC WORKS, INC.
Contractor Address: Unknown
Resident Engineer: Jeffrey Townsend Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2025-09-03-56
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 09/03/2025
Date that the sample was received by the laboratory/organization performing the testing: 09/10/2025
The quantity of what the sample constitutes: 1can
A brief description of the sample: Asphalt Rubber Binder
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: All American Asphalt-Irwindale

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2025-09-03-56-1
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 09/16/2025
Date Tested: 09/11/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 59 C
Softening Point Sample 2 59 C
Bath Liquid freshly boiled distilled water
Minutes Reaction no data

Test 2 of 3

DIME Test ID: 2025-09-03-56-2
Test Method: ASTM D217-21: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 09/16/2025
Date Tested: 09/12/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Determination Unworked Penetration
Unworked Penetration 44 0.1 mm

Test 3 of 3

DIME Test ID: 2025-09-03-56-3
Test Method: ASTM D5329-20: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 09/16/2025
Date Tested: 09/12/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Ball Penetration (P1) 6 mm
Final Dial reading (F1) 74 mm
Ball Penetration (P2) 7 mm
Final Dial reading (F2) 76 mm
Ball Penetration (P3) 4 mm
Final Dial reading (F3) 74 mm
Resilience 1 32 %
Resilience 2 31 %
Resilience 3 30 %
Average Resilience 31 %
Minutes Reaction no data