Print Report | Back to Sample Detail

Sample Record for 2025-09-11-32

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000501 DEA: 081J6104 EFIS: 0818000102 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-215-40.5/42.7
Work Description: INDIVIDUAL SLAB REPLACEMENT (RSC), RHMA, AND REPLACE BASE.
Location Description: RIVERSIDE COUNTY IN RIVERSIDE FROM 0.8 MILE SOUTH OF ROUTE 60/91 SEPARATION TO 0.4 MILE SOUTH OF MARTIN LUTHER KING BOULEVARD UNDERCROSSING
Contractor Name: FBD VANGUARD CONSTRUCTION, INC.
Contractor Address: 550 Greenville Rd., Livermore, CA
Resident Engineer: Mahfual Alam Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2025-09-11-32
TL Number from the TL Form: 1081-911
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 09/11/2025
Date that the sample was received by the laboratory/organization performing the testing: 09/13/2025
The quantity of what the sample constitutes: 3
A brief description of the sample: 6x12
From where was the sample collected: Job Site
Laboratory sample identification: 1081-911
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vanguard

Material Information

The concrete mix design number: Not Provided
The truck number from where the sample was collected: 244
The batch plant ticket number from where the sample was collected: 1
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: 215 SB Sta 586+00 - Lane 01
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2025-09-11-32-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617 - Sulfur Mortar Cap
Cured in accordance with ASTM C511
Verified Date: 09/22/2025
Date Tested: 09/18/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Cross sectional area of cylinder 1 28.56 in^2
Cross sectional area of cylinder 2 28.56 in^2
Cross sectional area of cylinder 3 28.56 in^2
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Compressive strength (to nearest 10 psi) 6940 psi
Average diameter of cylinder 1 6.03 in
Average diameter of cylinder 2 6.03 in
Compressive strength of cylinder 1 6986.0 psi
Compressive strength of cylinder 2 7087.7 psi
Average diameter of cylinder 3 6.03 in
Compressive strength of cylinder 3 6733.9 psi
Maximum load on cylinder 1 199520 lb
Maximum load on cylinder 2 202425 lb
Maximum load on cylinder 3 192320 lb
Type of fracture pattern of cylinder 1 3
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 7 days