Print Report | Back to Sample Detail

Sample Record for 2025-09-03-37

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 66667 DEA: JMFPP EFIS: 0019000043 QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for JMF Prequalification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2025-09-03-37
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 09/03/2025
Date that the sample was received by the laboratory/organization performing the testing: 09/03/2025
The quantity of what the sample constitutes: 3 bags
A brief description of the sample: JMFV
From where was the sample collected: Supplier
Laboratory sample identification: 25-09-03-37-JMFV
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Escondido

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-33-0027
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number: 220305 Esc Val

Test Results

Test 1 of 12

DIME Test ID: 2025-09-03-37-5
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 09/11/2025
Date Tested: 09/11/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested? Combined Gradation
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 94 %
Cumulative percent passing the 1/2 in. sieve 74 %
Cumulative percent passing the 3/8 in. sieve 60 %
Cumulative percent passing the #4 sieve 43 %
Cumulative percent passing the #8 sieve 31 %
Cumulative percent passing the #16 sieve 20 %
Cumulative percent passing the #30 sieve 14 %
Cumulative percent passing the #50 sieve 9 %
Cumulative percent passing the #100 sieve 6 %
Cumulative percent passing the #200 sieve 4.4 %

Test 2 of 12

DIME Test ID: 2025-09-03-37-8
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 09/11/2025
Date Tested: 09/10/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Sand Equivalent 69

Test 3 of 12

DIME Test ID: 2025-09-03-37-15
Test Method: CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)
Verified Date: 09/11/2025
Date Tested: 09/10/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Plastic limit (PL) 1 %

Test 4 of 12

DIME Test ID: 2025-09-03-37-6
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 09/11/2025
Date Tested: 09/10/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Method 1 - Combined Fracture Determination
Aggregate Size and Fracture Type Coarse 1 and 2 Faced
Percentage of questionable, coarse, 2 faced particles tested no data0 %
Percentage of questionable, coarse, 1 faced particles tested no data0 %
Percentage of fractured, coarse, 2 faced particles tested 100 %
Percentage of fractured, coarse, 1 faced particles tested 100 %

Test 5 of 12

DIME Test ID: 2025-09-03-37-7
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Verified Date: 09/11/2025
Date Tested: 09/10/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Method A
Determination By Number
Dimensional ratio used 5:1
Weighted percentage of particles (by number) that were flat no data0 %
Weighted percentage of particles (by number) that were elongated 0 %
Weighted percentage of particles (by number) that were both flat and elongated 0 %
Weighted percentage of particles (by number) that were neither flat nor elongated 100 %

Test 6 of 12

DIME Test ID: 2025-09-03-37-13
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 09/11/2025
Date Tested: 09/11/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7475.6 grams
Mass of oven-dry sample in air for Sample 1 1536.2 grams
Mass of container filled with the sample and water for Sample 1 8399.3 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.508
Theoretical maximum density at 25°C (77°F) 156.1 lb/ft^3

Test 7 of 12

DIME Test ID: 2025-09-03-37-9
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Verified Date: 09/11/2025
Date Tested: 09/11/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Bulk specific gravity 2.587
Bulk specific gravity (SSD Basis) 2.617
Apparent specific gravity 2.668
Absorption 1.2 %

Test 8 of 12

DIME Test ID: 2025-09-03-37-10
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Verified Date: 09/11/2025
Date Tested: 09/11/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Basis for relative density testing Bulk SSD
Specific Gravity 2.73
Absorption 0.8 %

Test 9 of 12

DIME Test ID: 2025-09-03-37-12
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Verified Date: 09/11/2025
Date Tested: 09/11/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What test method is performed? Method A
Bulk dry specific gravity 2.587
Average uncompacted voids 45.6 %

Test 10 of 12

DIME Test ID: 2025-09-03-37-14
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 09/11/2025
Date Tested: 09/11/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Is an aggregate correction factor used? No
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 100 %
Cumulative percent passing the 3/8 in. sieve 99 %
Cumulative percent passing the #4 sieve 77 %
Cumulative percent passing the #8 sieve 59 %
Cumulative percent passing the #16 sieve 45 %
Cumulative percent passing the #30 sieve 34 %
Cumulative percent passing the #50 sieve 24 %
Cumulative percent passing the #100 sieve 16 %
Cumulative percent passing the #200 sieve 10.8 %

Test 11 of 12

DIME Test ID: 2025-09-03-37-11
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Verified Date: 09/17/2025
Date Tested: 09/12/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Grading designation A
Mass of sample on No.12 sieve (after 500 revolutions) 4255 grams
Percent loss after 100 revolutions 6 %
Percent loss after 500 revolutions 15 %

Test 12 of 12

DIME Test ID: 2025-09-03-37-16
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 09/17/2025
Date Tested: 09/17/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Per 35-11
Test Result Compliance: complies
Additional Comments When Verified:
Is an aggregate correction factor used? No
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 95 %
Cumulative percent passing the 1/2 in. sieve 77 %
Cumulative percent passing the 3/8 in. sieve 70 %
Cumulative percent passing the #4 sieve 46 %
Cumulative percent passing the #8 sieve 35 %
Cumulative percent passing the #16 sieve 28 %
Cumulative percent passing the #30 sieve 15 %
Cumulative percent passing the #50 sieve 10 %
Cumulative percent passing the #100 sieve 7 %
Cumulative percent passing the #200 sieve 4.2 %