Sample Record for 2025-07-16-117
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 1000279 DEA: 023H70U4 EFIS: 0223000161
QA Service Level: 1
DIST-CO-RTE-PM: 02-TRI-299-15.0/25.7
Work Description: RHMA-G, HMA (TYPE A), COLD PLANE AC, & SOLDIER PILE RETAINING WALL.
Location Description: TRINITY COUNTY NEAR DEL LOMA FROM 1.0 MILE EAST OF TRINITY RIVER BRIDGE NO.05-0006 TO 0.1 MILE WEST OF PRAIRIE CREEK ROAD
Contractor Name: J.F. SHEA CONSTRUCTION, INC.
Contractor Address: Unknown
Resident Engineer: Edward Worden Structure Rep.: Mike Sears
Sample Information
DIME Sample ID: 2025-07-16-117
TL Number from the TL Form:
Sample Submitted By Organization: Precast Unlimited Inc.
Sample Organization Contact: (530) 243-6477
Type of Sample: Quality Control
Type of Material: Aggregate
Sample Taken Date: 07/16/2025
Date that the sample was received by the laboratory/organization performing the testing: 07/16/2025
The quantity of what the sample constitutes: 11997.4
A brief description of the sample: 1"x#4
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: J.F. Shea
Material Information
Source Identification (SMARA, name of Pit or Job Site): 91-45-0019
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: J.F. Shea Stockpile
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 1 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:
Test Results
Test 1 of 2
DIME Test ID: 2025-07-16-117-1
Test Method: ASTM C117-17: Standard Test Method for Materials Finer than 75-μm (No. 200) Sieve in Mineral Aggregates by Washing
Verified Date: 09/06/2025
Date Tested: 07/16/2025
Submitted By Organization: Precast Unlimited Inc.
Organization Address: 16538 Clear Creek Rd.,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: chase@precastunlimited.com
Organization Phone: 1 (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Percent finer than No. 200 sieve
|
1 %
|
Test 2 of 2
DIME Test ID: 2025-07-16-117-2
Test Method: ASTM C136-19: Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates
Verified Date: 09/06/2025
Date Tested: 07/18/2025
Submitted By Organization: Precast Unlimited Inc.
Organization Address: 16538 Clear Creek Rd.,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: chase@precastunlimited.com
Organization Phone: 1 (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
What type of gradation is being tested?
|
1 in. x No. 4 - Coarse Aggregate
|
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 in. sieve
|
99 %
|
|
Cumulative percent passing the 3/4 in. sieve
|
73 %
|
|
Cumulative percent passing the 1/2 in. sieve
|
16 %
|
|
Cumulative percent passing the 3/8 in. sieve
|
4 %
|
|
Cumulative percent passing the #4 sieve
|
2 %
|
|
Cumulative percent passing the #8 sieve
|
1 %
|