Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1001169 DEA: 07314524 EFIS: 0722000300 COOP: 075283
QA Service Level: 2
DIST-CO-RTE-PM: 07---
Work Description: I-105 METRO Express Lanes Project
Location Description: LA-105 PM R0.6/R10.1, LA-110 PM R14.1/R16.6
Contractor Name: Flatiron-Myers (JV)
Contractor Address: Unknown
Resident Engineer: Roger Miramontes Structure Rep.: Javid Sharifi
DIME Sample ID: 2025-07-31-57
TL Number from the TL Form:
Sample Submitted By Organization: Alta Vista Solutions - Whittier
Sample Organization Contact: (510) 542-9827
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 07/31/2025
Date that the sample was received by the laboratory/organization performing the testing: 07/31/2025
The quantity of what the sample constitutes: 10 CY
A brief description of the sample: CIDH Cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 25-0731_1
Structure unique identifier:
Structure name: EB 105 RW269
The fabricator/manufacturer/facility name: N/A
The concrete mix design number: 557237
The truck number from where the sample was collected: Truck or Ticket 391256
The batch plant ticket number from where the sample was collected: Load 1
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Jobsite
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2025-07-31-57-1
Test Method: CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement Concrete
Verified Date: 09/05/2025
Date Tested: 07/31/2025
Submitted By Organization: Alta Vista Solutions - Whittier
Organization Address: 12409 Slauson Avenue, Suite I,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90606
Organization Email: nicholas.hoffmann@oneatlas.com
Organization Phone: (510) 542-9827
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2025-07-31-57-2
Test Method: CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 09/05/2025
Date Tested: 07/31/2025
Submitted By Organization: Alta Vista Solutions - Whittier
Organization Address: 12409 Slauson Avenue, Suite I,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90606
Organization Email: nicholas.hoffmann@oneatlas.com
Organization Phone: (510) 542-9827
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2025-07-31-57-3
Test Method: CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement Concrete
Verified Date: 09/05/2025
Date Tested: 07/31/2025
Submitted By Organization: Alta Vista Solutions - Whittier
Organization Address: 12409 Slauson Avenue, Suite I,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90606
Organization Email: nicholas.hoffmann@oneatlas.com
Organization Phone: (510) 542-9827
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
DIME Test ID: 2025-07-31-57-4
Test Method: CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 09/05/2025
Date Tested: 07/31/2025
Submitted By Organization: Alta Vista Solutions - Whittier
Organization Address: 12409 Slauson Avenue, Suite I,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90606
Organization Email: nicholas.hoffmann@oneatlas.com
Organization Phone: (510) 542-9827
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified: