Print Report | Back to Sample Detail

Sample Record for 2025-09-04-40

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215620 DEA: 01436404 EFIS: 0100000193 QA Service Level: 1
DIST-CO-RTE-PM: 01-DN-101-35.8/36.5
Work Description: Dr. Fine Bridge Replacement
Location Description: DR. FINE BRIDGE REPLACEMENT FROM LAKE EARL DR TO S FRED D. HAIGHT DR ON HWY 101 ACROSS SMITH RIVER.
Contractor Name: MCM Construction
Contractor Address: PO Box 620, North Highlands, Ca 95660
Resident Engineer: Clayton Malmberg Structure Rep.: Brian Cinkutis

Sample Information

DIME Sample ID: 2025-09-04-40
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 09/04/2025
Date that the sample was received by the laboratory/organization performing the testing: 09/05/2025
The quantity of what the sample constitutes: 760
A brief description of the sample: 1" x 16-1/2" F1554 HH Gr. 105
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Portland Bolt

Material Information

Rocap Number(s):
Heat Number(s): 245623
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: F1554 Hvy Hex Gr. 105
Bolt Length(s): 16-1/2"
Nut Specification: N/A
Washer Specification: N/A
Finish: HDG
Diameter/Size: 1"
Bolt Mfg. Lot Number:
Rocap Test Requirement(s):
Lubricant Requirements(s):
Washer Inner Diameter(s):

Test Results

Test 1 of 7

DIME Test ID: 2025-09-04-40-1
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 09/15/2025
Date Tested: 09/05/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 245623
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PB AB105
Size 1 in
Bolt Length 16.5 in
Pitch Diameter 0.924 in
Pitch Diameter 2nd 0.924 in

Test 2 of 7

DIME Test ID: 2025-09-04-40-2
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 09/15/2025
Date Tested: 09/05/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) 245623
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PB AB105
Size 1 in
Bolt Length 16.5 in
Pitch Diameter .09325 in
Pitch Diameter 2nd 0.9325 in

Test 3 of 7

DIME Test ID: 2025-09-04-40-3
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 09/15/2025
Date Tested: 09/05/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) 245623
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PB AB105
Size 1 in
Bolt Length 16.5 in
Pitch Diameter 0.936 in
Pitch Diameter 2nd 0.936 in

Test 4 of 7

DIME Test ID: 2025-09-04-40-4
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/15/2025
Date Tested: 09/12/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 245623
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 1 in
Bolt Length 16.5 in
Measurement Average 5.4 mils

Test 5 of 7

DIME Test ID: 2025-09-04-40-5
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/15/2025
Date Tested: 09/12/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) 245623
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 1 in
Bolt Length 16.5 in
Measurement Average 6.8 mils

Test 6 of 7

DIME Test ID: 2025-09-04-40-6
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/15/2025
Date Tested: 09/12/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) 245623
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 1 in
Bolt Length 16.5 in
Measurement Average 5.1 mils

Test 7 of 7

DIME Test ID: 2025-09-04-40-7
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 09/15/2025
Date Tested: 09/12/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 3
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
1A24562310.6061230201362870W Torres
1B24562310.6061210891359410W Torres
1C24562310.6061252971374420W Torres
UTM NA
Temperature 72 f