Sample Record for 2025-09-04-12
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 993825 DEA: 040Q30U4 EFIS: 0420000235 COOP: 042830A3,042830A4
QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA,CC-680-R11.0/R21.9,R0.0/R0.9
Work Description: PRECAST CONC PVMT, ELECTRONIC TOLL SYSTEM, JPCP, CB & STRUCTURAL CONC
Location Description: ALAMEDA AND CONTRA COSTA COUNTIES AT SUNOL AND IN SAN RAMON BETWEEN 0.4 MILE SOUTH OF CALAVERAS ROAD UNDERCROSSING TO 0.9 MILE NORTH OF ALCOSTA BOULEVARD OVERCROSSING
Contractor Name: BAY CITIES PAVING & GRADING (Jason Ochoa)
Contractor Address: 1450 CIVIC CT, BLDG B #400, CONCORD, CA 94520
Resident Engineer: Yannaing Tun Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2025-09-04-12
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 09/04/2025
Date that the sample was received by the laboratory/organization performing the testing: 09/05/2025
The quantity of what the sample constitutes: 24
A brief description of the sample: 1 3/4"-5X48"
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Blue Circle Corp
Material Information
Rocap Number(s):
Heat Number(s): 3136496
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: ASTM F1554 gr55
Bolt Length(s): 48
Nut Specification: N/A
Washer Specification: N/A
Finish: ASTM F2329
Diameter/Size: 1 3/4"
Bolt Mfg. Lot Number:
Rocap Test Requirement(s):
Lubricant Requirements(s):
Washer Inner Diameter(s):
Test Results
Test 1 of 3
DIME Test ID: 2025-09-04-12-1
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 09/15/2025
Date Tested: 09/09/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
3136496
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
YELLOW
|
|
Size
|
1.75 in
|
|
Bolt Length
|
48 in
|
|
Pitch Diameter
|
1.6150 in
|
|
Pitch Diameter 2nd
|
1.6150 in
|
Test 2 of 3
DIME Test ID: 2025-09-04-12-2
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/15/2025
Date Tested: 09/15/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
3136496
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
1.75 in
|
|
Bolt Length
|
48 in
|
|
Measurement Average
|
4.4 mils
|
Test 3 of 3
DIME Test ID: 2025-09-04-12-3
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 09/15/2025
Date Tested: 09/15/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Bolt Samples
|
1
|
| Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | | 1A | 3136496 | 1.75 | 157400 | 0000 | 0000 | yield 144670 | Kleinfelder |
| |
|
UTM
|
NA
|
|
Temperature
|
0 f
|