Print Report | Back to Sample Detail

Sample Record for 2025-08-26-33

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000320 DEA: 11430324 EFIS: 1118000102 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-805-14.6/23.7
Work Description: MODIFY ELECTRICAL, CONCRETE PAVEMENT, DRAINAGE AND SIGNS.
Location Description: SAN DIEGO COUNTY IN SAN DIEGO FROM ROUTE 805/15 SEPARATION TO 0.1 MILE NORTH OF ROUTE 805/52 SEPARATION
Contractor Name: COFFMAN SPECIALTIES, INC.
Contractor Address: 9685 VIA EXCELENCIA STE 200, SAN DIEGO, CA 92126
Resident Engineer: Art Pannu Structure Rep.: Anh Ma

Sample Information

DIME Sample ID: 2025-08-26-33
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 08/26/2025
Date that the sample was received by the laboratory/organization performing the testing: 08/27/2025
The quantity of what the sample constitutes: 2 bags
A brief description of the sample: JMF
From where was the sample collected: Job Site
Laboratory sample identification: 25-08-26-33-JMF
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Robertson's Miramar

Material Information

Source Identification (SMARA, name of Pit or Job Site): Not Provided
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number: 23418180AH MM

Test Results

Test 1 of 10

DIME Test ID: 2025-08-26-33-3
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 09/05/2025
Date Tested: 09/04/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Sand Equivalent 78

Test 2 of 10

DIME Test ID: 2025-08-26-33-1
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 09/05/2025
Date Tested: 09/04/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Method 1 - Combined Fracture Determination
Aggregate Size and Fracture Type Coarse 1 and 2 Faced
Percentage of questionable, coarse, 2 faced particles tested no data0 %
Percentage of questionable, coarse, 1 faced particles tested no data0 %
Percentage of fractured, coarse, 2 faced particles tested 99 %
Percentage of fractured, coarse, 1 faced particles tested 98 %

Test 3 of 10

DIME Test ID: 2025-08-26-33-2
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Verified Date: 09/05/2025
Date Tested: 09/04/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Method A
Determination By Number
Dimensional ratio used 5:1
Weighted percentage of particles (by number) that were flat no data0 %
Weighted percentage of particles (by number) that were elongated 0 %
Weighted percentage of particles (by number) that were both flat and elongated 0 %
Weighted percentage of particles (by number) that were neither flat nor elongated 100 %

Test 4 of 10

DIME Test ID: 2025-08-26-33-8
Test Method: CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)
Verified Date: 09/05/2025
Date Tested: 09/04/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Plastic limit (PL) 1 %

Test 5 of 10

DIME Test ID: 2025-08-26-33-10
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 09/11/2025
Date Tested: 09/05/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested? Combined Gradation
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 97 %
Cumulative percent passing the 1/2 in. sieve 84 %
Cumulative percent passing the 3/8 in. sieve 68 %
Cumulative percent passing the #4 sieve 35 %
Cumulative percent passing the #8 sieve 27 %
Cumulative percent passing the #16 sieve 16 %
Cumulative percent passing the #30 sieve 9 %
Cumulative percent passing the #50 sieve 5 %
Cumulative percent passing the #100 sieve 2 %
Cumulative percent passing the #200 sieve 1.4 %

Test 6 of 10

DIME Test ID: 2025-08-26-33-5
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Verified Date: 09/11/2025
Date Tested: 09/05/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Basis for relative density testing Bulk SSD
Specific Gravity 2.737
Absorption 1 %

Test 7 of 10

DIME Test ID: 2025-08-26-33-6
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Verified Date: 09/11/2025
Date Tested: 09/05/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Grading designation C
Mass of sample on No.12 sieve (after 500 revolutions) 4327 grams
Percent loss after 100 revolutions 4 %
Percent loss after 500 revolutions 14 %

Test 8 of 10

DIME Test ID: 2025-08-26-33-4
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Verified Date: 09/11/2025
Date Tested: 09/08/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Bulk specific gravity 2.593
Bulk specific gravity (SSD Basis) 2.620
Apparent specific gravity 2.665
Absorption 1 %

Test 9 of 10

DIME Test ID: 2025-08-26-33-7
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Verified Date: 09/11/2025
Date Tested: 09/08/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What test method is performed? Method A
Bulk dry specific gravity 2.593
Average uncompacted voids 46 %

Test 10 of 10

DIME Test ID: 2025-08-26-33-9
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 09/12/2025
Date Tested: 09/12/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Is an aggregate correction factor used? No
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 96 %
Cumulative percent passing the 1/2 in. sieve 84 %
Cumulative percent passing the 3/8 in. sieve 70 %
Cumulative percent passing the #4 sieve 36 %
Cumulative percent passing the #8 sieve 26 %
Cumulative percent passing the #16 sieve 18 %
Cumulative percent passing the #30 sieve 13 %
Cumulative percent passing the #50 sieve 9 %
Cumulative percent passing the #100 sieve 6 %
Cumulative percent passing the #200 sieve 3.9 %